Hearth and Home Technologies SL-750TR-D Furnace User Manual


 
Heat & Glo • SL-550 / 750 / 950TR-D • InD • 2044-985 Rev. M • 10/0614
Figure 5.4
E. Vent Diagrams
Top Vent - Horizontal Termination
Venting with 1 elbow (NG)
H
1
V
1
V Minimum
H
1
Maximum
SL-550TR-D SL-750TR-D SL-950TR-D
90 Elbow 2 ft. 610 mm 2 ft. 610 mm 1 ft. 305 mm
0.5 ft. 152 mm 2 ft. 610 mm 2 ft. 610 mm 2 ft. 610 mm
1.5 ft. 457 mm 3 ft. 914 mm 3 ft. 914 mm 3 ft. 914 mm
2.5 ft. 762 mm 5 ft. 1.5 m 5 ft. 1.5 m 5 ft. 1.5 m
3.5 ft. 1.1 m 7 ft. 2.1 m 7 ft. 2.1 m 7 ft. 2.1 m
4.5 ft. 1.4 m 15 ft. 4.6 m 15 ft. 4.6 m 15 ft. 4.6 m
H MAX. =15 FT (4.6 m)
V + H MAX. = 40 FT (12.2 m)
Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles between ceiling restops.
ALWAYS maintain speci ed clearances around venting and restop systems.
Install wall shield and ceiling restops as speci ed.
Failure to keep insulation or other material away from vent pipe may cause re.
WARNING
NOTE: There MUST be a 25%
reduction in total H when using
ex vent except when using the
simple up and out installation
(see Figure 5.3).
Note: Use SL D- Series
components only.
V Minimum
H
1
Maximum
SL-550TR-D SL-750TR-D SL-950TR-D
90 Elbow 1.5 ft. 457 mm Not allowed Not allowed
0.5 ft. 152 mm 1.5 ft. 457 mm 1 ft. 305 mm 1 ft. 305 mm
1.5 ft. 457 mm 3 ft. 914 mm 3 ft. 914 mm 3 ft. 914 mm
2.5 ft. 762 mm 5 ft. 1.5 m 5 ft. 1.5 m 5 ft. 1.5 m
3.5 ft. 1.1 m 7 ft. 2.1 m 7 ft. 2.1 m 7 ft. 2.1 m
4.5 ft. 1.4 m 15 ft. 4.6 m 15 ft. 4.6 m 15 ft. 4.6 m
H MAX. =15 FT (4.6 m)
V + H MAX. = 40 FT (12.2 m)
Top Vent - Horizontal Termination
Venting with 1 elbow (Propane)