Hearth and Home Technologies SL-750TR-D Furnace User Manual


 
Heat & Glo • SL-550 / 750 / 950TR-D • InD • 2044-985 Rev. M • 10/0616
Figure 5.6
H
2
V
2
H
1
V
1
Top Vent - Horizontal Termination
Venting with 3 elbows (NG)
V Minimum
H
1
+ H
2
Maximum
SL-550TR-D SL-750TR-D SL-950TR-D
90 Elbow 2 ft. 610 mm 2 ft. 610 mm 2 ft. 610 mm
0.5 ft. 152 mm 6 ft. 1.8 m 6 ft. 1.8 m 6 ft. 1.8 m
1.5 ft. 457 mm 10 ft. 3.0 m 10 ft. 3.0 m 10 ft. 3.0 m
2.5 ft. 762 mm 12 ft. 3.7 m 12 ft. 3.7 m 12 ft. 3.7 m
3.5 ft. 1.1 m 14 ft. 4.3 m 14 ft. 4.3 m 14 ft. 4.3 m
H + H
1
MAX. =14 FT (4.6 m)
V + V
1
+ H + H
1
MAX. = 40 FT (12.2 m)
V Minimum
H
1
+ H
2
Maximum
SL-550TR-D SL-750TR-D SL-950TR-D
90 Elbow 2 ft. 610 mm Not allowed Not allowed
0.5 ft. 152 mm 6 ft. 1.8 m 6 ft. 1.8 m 6 ft. 1.8 m
1.5 ft. 457 mm 10 ft. 3.0 m 10 ft. 3.0 m 10 ft. 3.0 m
2.5 ft. 762 mm 12 ft. 3.7 m 12 ft. 3.7 m 12 ft. 3.7 m
3.5 ft. 1.1 m 14 ft. 4.3 m 14 ft. 4.3 m 14 ft. 4.3 m
H + H
1
MAX. =14 FT (4.6 m)
V + V
1
+ H + H
1
MAX. = 40 FT (12.2 m)
Top Vent - Horizontal Termination
Venting with 3 elbows (Propane)
NOTE: There MUST be a 25%
reduction in total H when using
ex vent except when using the
simple up and out installation
(see Figure 5.3).
Note: Use SL D- Series
components only.