Installation of Upper Clearance Spacer for Vertical Vent (Figure 2)
Included with every fireplace is the upper clearance spacer. The upper
clearance spacer must be attached to the top of the firebox before
installation of fireplace in a vertical vent configuration.
1. Remove screw in firebox top that is behind 1/4" flange on vent
cover plate and directly in front of adapter pipe.
2. Place the notched portion of upper clearance spacer facing the 1/4"
flange on vent cover plate.
3. Flex firebox top and slide upper clearance spacer beneath vent
cover plate.
4. Attach upper clearance spacer to firebox top with screw from Step
1.
5. Installation of upper clearance spacer is completed.
The upper clearance spacer will prevent combustible material from
contacting adapter pipe.
VENT COVER
PLATE