Empire Comfort Systems DVF-36-2 Indoor Fireplace User Manual


 
Page 36 R-5627
OPTIONAL FRESH FIREPLACE
AIR INTAKE KIT MODEL NUMBERS
FB-AK-2 DVF-36 DVF-36IP
DVF-42 DVF-42IP
Optional Fresh AIr Intake Kit (Figure 1)
Installation of our 6" fresh air intake kit is simple and easy to complete. This system MUST BE installed before the fireplace is enclosed with finishing
material. The air will be drawn into the cooling layer of the fireplace and be completely separated from the combustion casing of the direct vent fireplace.
Cooler outside air will mix with room air, circulating around the firebox to reduce the heat output and bring heated, fresh air into the house to provide a
more positive balance.
Installing Fresh Air Intake Kit (Figures 2, 3, 4, 5)
1. Remove air dilution cover plate from left side of outer casing by
removing (4) 10 x 1/2" screws (See Figure 2).
2. Attach damper assembly onto left side of outer casing with (4)
10 x 1/2" screws from Step 1. The 3" damper door tab will be
positioned to the right as the damper assembly is attached to left
side of outer casing.
3. As you face the fireplace, insert damper rod bracket into left,
interior bottom of fireplace. The 3/4" flange on damper rod
bracket must face toward the rear of fireplace. Align (2) clearance
OUTER
CASING
REMOVE
AIR DILUTION
COVER PLATE
Figure 3 Top View of Air System Installation
OUTER
CASING
GASKET
TOP VIEW
DAMPER
ASSEMBLY
COVER
PLATE
DAMPER ROD (OPEN)
DAMPER
ROD BRACKET
DAMPER
ROD (CLOSED)
Figure 2 Damper Assembly Location
Figure 1 Fresh Air Intake Kit
RAIN CAP
INCLUDES
OUTSIDE AIR
TUBE ASSEMBLY
DAMPER
ASSEMBLY
INCLUDES
DAMPER
ROD
*DAMPER
ROD
BRACKET
COVER
PLATE
holes on damper rod bracket with (2) screw holes on left side of
hearth pan. Attach damper rod bracket to the underside of hearth
pan with (2) 10 x 1/2" provided screws (See Figure 3).
*Attention: