Carrier 50SS018-060 Air Conditioner User Manual


 
REQUIRED CLEARANCES TO COMBUSTIBLE MATERIAL in. (mm)
Unit Top ........................................14(356)
Duct Side of Unit ...................................2(51)
Side Opposite Ducts ...............................14(356)
Bottom of Unit .........................................0
Vertical Discharge First 12 in. (305) of Supply Duct ...........1(25)
NECESSARY REQUIRED CLEARANCES in. (mm)
Between Units, Control Box Side .....................42(1067)
Unit and Ungrounded Surfaces, Control Box Side ...........36(914)
Unit and Block or Concrete Walls and Other Grounded
Surfaces, Control Box Side .........................42(1067)
REQUIRED CLEARANCES FOR SERVICING in. (mm)
Evaporator Coil Access Side .........................30(762)
Control Box Access Side ............................30(762)
(Except for Necessary Requirements)
Unit Top ........................................36(914)
Side Opposite Ducts ...............................30(762)
NOTES:
1. Clearances mustbemaintained topreventrecirculation ofair fromoutdoor-
fan discharge.
2. Dimensions in ( ) are in millimeters.
UNIT
50SX
CENTER OF GRAVITY (in./mm)
XYZ
042 20.8/529 20.2/512 17.3/440
048 21.6/548 19.8/502 17.3/440
060 22.0/560 19.9/506 15.7/399
LEGEND
CG Center of Gravity NEC National Electrical Code
COND Condenser REQ’D Required
MAT’L Material
UNIT
50SX
ELECTRICAL
CHARACTERISTICS
UNIT WT CORNER WT (Lb/Kg)
Lb Kg A B C D
042 208/230-1-60, 208/230-3-60, 460-3-60 329 150 89/40 64/29 124/56 52/24
048 208/230-1-60, 208/230-3-60, 460-3-60 360 164 89/40 75/34 138/63 58/26
060 208/230-1-60, 208/230-3-60 379 172 70/32 104/47 125/57 80/36
Fig. 9 Dimensions; Units 50SX042-060 With Optional Base Rail (cont)
11