A SERVICE OF

logo

1218 | E-Series TeraScale Debugging and Diagnostics
www.dell.com | support.dell.com
Flexible packet classifier hardware errors
FTOS displays Message 19 in case of a parity error on an FPC. Configure an action using the command
hardware monitor linecard asic fpc action-on-error. You may place the line card in a problem state, reset the
card, or shutdown all ports on the card.
Line card MAC hardware errors
FTOS displays Message 20 in case of a port hang error. Configure an action using the command hardware
monitor mac action-on-error port-shutdown
. You may only shutdown all ports on the card with this
command.
Core dumps
RPM core dumps
The RPM supports two types of core dumps for RPMsā€”application and kernel.
Message 17 Low Free Memory Error
%RPM0-P:CP %CHMGR-1-LF_MEM_ERR: Low free memory error detected on Ingress BTM port-pipe 0
Line card slot 9
%RPM0-P:CP %CHMGR-1-LF_MEM_ERR: Low free memory error detected on Egress BTM port-pipe 1 Line
card slot 9
Message 18 Start-of-Packet/End-of-Packet Memory Error
%RPM0-P:CP %CHMGR-1-SOP_EOP_ERR: SOP/EOP error detected on Ingress BTM port-pipe 1 Line card
slot 9
%RPM0-P:CP %CHMGR-1-SOP_EOP_ERR: SOP/EOP error detected on Unknown slot 9
Message 19 Parity Error
%RPM0-P:CP %CHMGR-2-CARD_PARITY_ERR: Linecard 9 pp 0 FPC SRAM Hard parity error: Address
0x85000 Index 0x80000 Check the Hardware Log
%E48TF:9 %POLLMGR-5-FPC_NOTIFY: Line card detected FPC 9 parity - Transient phantom
%E48TF:9 %POLLMGR-5-FPC_NOTIFY: Line card detected FPC 9 parity - Transient recoverable
Message 20 Port Hang Error
%E48TF:9 %IFAGT-5-PORT_HUNG: Port hang detected on slot 9 port 2
%E48TF:9 %IFAGT-5-PORT_HUNG: Port hang detected on slot 9 port 26