York R-407C Air Conditioner User Manual


 
YORK INTERNATIONAL
14
Physical Data (continued)
TABLE 1 – PHYSICAL DATA – MODELS 75-95
MODEL SIZE 075 080 085 090 095
GENERAL DATA
Length (cm) w/o Hood 1140 1140 1140 1240 1240
Width (cm) w/o Hood 234 234 234 234 234
Height (cm) 208 208 208 234 234
Operating Weights (Kg) (Base Unit, No Options)
Cooling Only (Rigging & R407C) 5897 5994 6092 6496 6594
Option Weights (Kg)
Power Exhaust (Blower, Motor, Fan Skid & Mod Damper) 341 341 341 347 347
Power Exhaust (Blower, Motor, Fan Skid, VFD & Baro Damper) 332 332 332 337 337
100% AMS (Measurement Station & Mounting) 57 57 57 64 64
25/75% AMS (Measurement Station & Mounting) 66 66 66 73 73
Min. AMS (Measurement Station & Mounting) 20 20 20 23 23
Barometric Only 20 20 20 25 25
375 MBH Gas Heat 73 73 73 73 73
750 MBH Gas Heat 147 147 147 147 147
1125 MBH Gas Heat 220 220 220 220 220
40 kW 204 204 204 222 222
80 kW 231 231 231 249 249
108 kW 213 213 213 231 231
150 kW 222 222 222 240 240
200 kW 231 231 231 249 249
250 kW 240 240 240 259 259
Condenser Wire Guard 18 18 18 20 20
Copper Condenser Coils (Additional) 280 480 480 540 540
Copper Evaporator Coils (Additional) 209 127 209 209 263
Roof Curb Weights (Kg)
14" Full Perimeter Roof Curb 463 463 463 472 472
14" Open Condenser Roof Curb 262 262 262 279 279
Compressor Data
Quantity/Size (Nominal Hp) 4x10, 2x13 6x13 6x13 2x13, 4x15 2x13, 4x15
Type Scroll Scroll Scroll Scroll Scroll
Capacity Steps (%) 4x15, 2x20 6x16 6x16 4x18, 2x15 4x18, 2x15
Supply Fan and Drive
Quantity 1 1 1 1 1
Type FC FC FC FC FC
Size 28-25 28-25 28-25 28-28 28-28
Motor Size Range (Min. to Max. Hp) 7.5-60 7.5-60 7.5-60 7.5-60 7.5-60
Air Flow Range (Min. to Max. m3/hr) 23785-54,367 23785-54,367 30582-61164 30582-61164 30582-61164
Static Pressure Range (Min. to Max. ESP) 0-995 Pa 0-995 Pa 0-995 Pa 0-995 Pa 0-995 Pa
Exhaust Fan
Quantity 2 2 2 2 2
Type FC FC FC FC FC
Size 18-18 18-18 18-18 18-18 18-18
Motor Size Range (Min. to Max. HP) 10-20 10-20 10-20 10-20 10-20
Air Flow Range (Min. to Max. m3/hr) 0-33980 0-33980 0-33980 0-33980 0-33980
Static Pressure Range (Min. to Max. ESP) 0-498 Pa 0-498 Pa 0-498 Pa 0-498 Pa 0-498 Pa