Quadra-Fire 7046-137C Indoor Fireplace User Manual


 
Page 24
7046-137C
December 15, 2009
R
2700-I ACC Wood Insert
F. Tube Channel Assembly Replacement
Figure 24.3
Removing Tube Channel Assembly
1. Remove the  bottom bricks rst and then remove the  right
side bricks.
2. Remove the bafe protection channel by bending back the tabs
using needle nose pliers located at the right and left side of the
protection cover. Lift the cover up slightly and pull toward the
front and out of the rebox. Figure 24.1.
. Locate the 2 channel nuts inside of chamber and remove using a
7/16 socket wrench. Figure 24.2.
NOTE: Soak the bolts with penetrating oil for at least 15 minutes
before trying to remove them.
4. Slide the tube channel assembly all the way to left until it is off the
threads. Drop the right side down, then slide the assembly back
to right. Figure 24.3.
5. The ceramic blanket and both bafe boards can be removed at
the same time you remove the tube channel assembly.
6. When the tube channel assembly is free of the left side sup-
port, rotate clockwise and pull assembly, blanket and bafes out
through the front opening.
7. Re-install in reverse order.
2 Tube Channel Nuts
Tube Channel
Assembly
Ceramic Blanket
Baffle Boards
Baffle Protection Channel
2
1
1
1
3
4
1
2
4
3
Rotate and
remove from
firebox
Baffle Protection
Channel
Bend Back Tabs
Use 7/16 Socket Wrench
and Remove Channel Nuts
Figure 24.1
Figure 24.2