2700-I ACC Wood Insert
Q. Opacity (Smoke)
Opacity is the measure of how cleanly your appliance is
burning.
Opacity is measured in percent:
100% opacity is when an object is totally obscured by
the smoke column from a chimney, and
0% opacity means that no smoke column can be seen.
As you become familiar with your appliance, you should
periodically check the opacity. This will allow you to know
how to burn as nearly smoke-free as possible (goal of 0%
opacity).
P. Frequently Asked Questions
ISSUES SOLUTIONS
Odor from appliance When rst operated, this appliance may release an odor for the rst several hours. This is
caused by the curing of the paint and the burning off of any oils remaining from manufacturing.
Metallic noise Noise is caused by metal expanding and contracting as it heats up and cools down, similar to
the sound produced by a furnace or heating duct. This noise does not affect the operation or
longevity of the appliance.
Whirring sound The blower may produce a whirring sound which increases in volume as the speed is
increased.
Odors and vapors released during initial operation.
Curing of high temperature paint.
Open windows for air circulation.
Odors may be irritating to sensitive individuals.
CAUTION
Figure 16.1 - Clear Space
O. Clear Space
Do NOT place combustible objects within 4 ft (1.2 m) of
the front of replace. Figure 16.1.
Do NOT place combustible objects within 48
inches in front of the appliance.
High temperatures may ignite clothing, furniture or
draperies.
Fire Risk.
WARNING
CLEAR SPACE
4 FT (1.2m) IN
FRONT OF INSERT
NOTICE!
Do NOT operate a circulating fan within close prox-
imity, approximately 4 ft (1.2m), of appliance
• Can reverse air ow, blowing hot air into appli-
ance cavity.
• Can damage appliance blower due to overheat-
ing.