December 15, 2009
7046-137C
Page 11
2700-I ACC Wood Insert
R
3. Burn Rate Air Control
• The air supply enters at the upper front of the rebox,
near the top of the glass door.
• This preheated air supplies the necessary fresh oxygen
to mix with the unburned gases, helping to create the
second, third and fourth combustion process.
• This air is regulated by the Burn Rate Air Control.
• There are four settings High, Medium-High, Medium-Low
and Low.
• When the control is raised all the way up it is on the High
setting and when pushed all the down it is on the Low
setting. Figure 11.1.
I. Burn Rates and Operating Efciency
For maximum operating efciency
1. This appliance has a timer system (ACC) that operates
the appliance at its maximum efciency removing any
guess work for the homeowner. Follow the instructions
below for each burn rate for the Start-Up Air Control and
Burn Rate Air Control. Figure 11.1.
2. Burn dry, well-seasoned wood.
Burn Rates
1. Starting a Fire and Reloading
• Open both controls fully by raising the Burn Rate Air Con-
trol all the way up until it stops and push the Start-up Air
Control back until it stops.
•
The blower tends to cool the appliance. Leave the blower
off until the burn is well established, i.e., 0 minutes.
• After loading the appliance with wood and starting the
re, set both controls to the desired setting by following
the burn rate instructions below.
2. High Burn Rate - Maximum Heat*
•
Raise the Burn Rate Air Control all the way up until it stops
(top marker) to a fully open position.
•
Push the Start-Up Air Control all the way back until it stops
and leave it there.
•
This setting over-rides the timer system (ACC) so you
must monitor the re closely while in this setting.
3.
Medium-High Burn Rate - 15,000 to 30,000 BTU/hr*
• Raise the Burn Rate Air Control all the way up until it
stops (top marker) to a fully open position.
• Push the Start-Up Air Control all the way back until it
stops and then pull forward until it stops.
• This activates the timer system (ACC).
4.
Medium-Low Burn Rate - 10,000 to 15,000 BTU/hr*
• Raise the Burn Rate Air Control up to the bottom of the
middle marker and stop.
Figure 11.1 Activating Timer
NOTE: If control is set full inward on “HI” it over-rides the
timer (ACC).
*NOTE:
These are approximate settings, and will vary with
type of wood or chimney draft. Due to altitude and other
environmental circumstances, this operational information is
a guideline only.
• Push the Start-Up Air Control until it stops.
• This activates the timer system (ACC).
5. Low Burn Rate - Below 10,000 BTU/hr*
• Leave the Burn Rate Air Control at the bottom marker.
• Push the Start-Up Air Control all the way back until it
stops and then pull forward until it stops.
• This activates the timer system (ACC).
WARNING
Risk of Fire.
When set on High Burn Rate and over-riding
the Automatic Combustion Control system an
overre situation can occur and may result in a
chimney re.
Overring will void the stove warranty.
HIGH
LOW
Burn Rate
Air Control
Start-Up Air Control
IN / OUT
High (Opened)
Low (Closed)