Quadra-Fire 7046-137C Indoor Fireplace User Manual


 
Page 12
7046-137C
December 15, 2009
R
2700-I ACC Wood Insert
CORRECT POSITION
INCORRECT POSITIONS
Firebox damage due to improper bafe place-
ment is not covered by warranty. Operate the
wood burning appliance with the bafe in the
correct position only.
Not doing so could result in:
Reduced efciency
Overheating the chimney
Overheating the rear of the rebox
Poor performance
WARNING
Fire Risk
Ensure correct bafe placement and replace bafe com-
ponents if damaged or missing.
J. Correct Bafe & Blanket Placement
Ceramic Blanket and Bafe Board are NOT
in contact with the back of the rebox.
Ceramic Blanket is NOT in contact with the
back of the rebox and NOT even with the
Bafe Board in the front.
Ceramic Blanket is bunched up at the back
of the rebox and NOT even with the Bafe
Board in the front.
Ceramic Blanket
Back of Firebox
Baffle Board
Ceramic Blanket and Bafe Board MUST be
in contact with the back of the rebox and
even with each other in the front.
Ceramic Blanket
Back of Firebox
Baffle Board
Figure 12.1 - Correct Bafe and Blanket Positions Figure 12.2 - Incorrect Bafe and Blanket Positions