Quadra-Fire 7046-137C Indoor Fireplace User Manual


 
December 15, 2009
7046-137C
Page 19
2700-I ACC Wood Insert
R
G. Quick Reference Maintenance Overview Guide for Wood Appliances.
2
2
Bafe and blanket placement is critical to heat out-
put, efciency and overall life of the unit. Make sure
the bafe is pushed all of the way to the back of the
rebox and the blanket is laying at.
Firebrick is designed to protect your rebox. Replace
rebricks that are crumbling, cracked or broken. If
you have an optional ash door, check to make sure
the door is closing properly.
The chimney and chimney
cap must be inspected for
soot and creosote during
the burn season. This will
prevent pipe blockage, poor
draft, and chimney res.
Always burn dry wood to
help prevent cap blockage
and creosote build-up.
Keeping the door and glass
gasket in good shape will
maintain good burn times on
a low burn setting.
Check the glass frame for
loose screws to prevent air
leakage.
Check the door latch for proper adjustment. This
is very important especially after the door rope has
formed to the stove face.
Start the rst inspection of your unit af-
ter the rst 2 months of use, or if perfor-
mance changes, and adjust your sched-
ule accordingly.
BAFFLE & BLANKET PLACEMENT
INSPECT FIREBRICKS & ASH COVER
(AFTER EACH CLEANING)
CHIMNEY & CAP INSPECTION
DOOR & LATCH CHECK
Step Top Models Only
Maintenance is required for safe oper-
ation and must be performed to main-
tain your warranty.