Page 10
7046-137C
December 15, 2009
R
2700-I ACC Wood Insert
H. Air Controls
1. Start-Up Air Control
The function of the Start-Up Air Control is to activate the
Automatic Combustion Control system (ACC).
• Push the Start-Up Air Control all the way back until it stops
and then pull forward to the front of the appliance until it
stops. Figure 10.1.
• The air channel opens and allows air to enter the front of
the appliance for approximately 20-25 minutes.
• The air channel gradually shuts down until it is completely
closed at the end of the 20-25 minutes.
• The re is now controlled by the air supplied by the Burn
Rate Air Control. Figure 10.1.
• This function should be performed each time you reload
the appliance.
2. Manual Timer Over-Ride
If you need to shut the ACC system off before it shuts itself off
after 25 minutes (i.e. overre situation), lift up on the Start-up
Air Control and pull away from the appliance. Figure 10.2.
Figure 10.1 Start-up and Burn Rate Air Cont
rols
Figure 10.2 Manual Timer Over-Ride
G. Automatic Combustion Control (ACC)
Typically, when you build a re, you open the air controls fully
and monitor the re to prevent it from going into an overre
situation and/or burning your wood up too quickly before you
shut down the air controls to the desired burn rate.
When using the Automatic Combustion Control (ACC) system,
you do not have to continually monitor the re. Once you
set the ACC system it will control the re for you. Follow the
instructions below to learn how to operate your stove with
ease.
Start-up Air
Control
Push back until it stops
then pull forward
Burn Rate
Air Control
HIGH
MED
LOW
Lift Up on Control and Pull
Away from Appliance