5
Service Parts Replacement
A. Glass Replacement
(Replace with 5mm ceramic glass only)
1. Ensure that the re is out and the appliance is cool to
the touch.
2. Protect a table or counter top with padding or towels.
Protect your hands and wear gloves to prevent injury.
3. Remove the door with the broken glass by lifting the
door up and off of the hinges.
4.
Lay door face down on a table or counter making sure
the handle hangs over the edge so the door lays at, on
a soft surface.
5. Remove the screws from each glass retainer and remove
the glass. (If screws are difcult to remove, soak with
penetrating oil rst).
6. Center the glass with edges evenly overlapping the
opening in the door, (i.e. same space top and bottom,
left and right sides).
7. Replace the glass retainers. Be careful not to cross
thread the screws.
8. Tighten each retainer just a few turns until each is
secured. Check again for centering of glass in door
frame. Continue to tighten each retainer alternately, a
few turns at a time, until the glass is secure. DO NOT
OVERTIGHTEN - can cause glass to break.
9. Replace the door on the appliance.
Quadra-Fire appliances are equipped with ceramic super
heat-resistant glass, which can only be broken by impact or
misuse.
WARNING! Risk of Fire or Injury!
CAUTION!
B. Snap Disc Replacement
Figure 21.1 Snap Disc Location
1. Locate the snap disc bracket assembly in the blower
housing under the ash lip. Figure 21.1
2. Using a 5/2 Allen wrench, remove the 4 mounting bolts
and slide assembly towards you.
. Using a Phillips head screw driver, remove the 2 screws
from the snap disc and lift the snap disc off of the mounting
bracket. Disconect the wires and replace with new snap
disc and re-connect the wires. Figure 21.2.
4. Slide the blower housing back into position and secure with
the 4 mounting bolts.
Figure 21.2
Remove Bolts and Slide
Blower Assembly Out
Snap Disc Location
Snap Disc