Goodman Mfg MH95/ACSH96/AMEH96/ GCH95/GME95/GCH9 Furnace User Manual


 
46
1. CFM in chart is without filters(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes
both filters are installed.
2. All furnaces ship as high speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed.
3. For most jobs, about 400 CFM per ton when cooling is desirable.
4. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.
5. The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. The shaded area indicates ranges
in excess of maximum external static pressure allowed when heating. The data for 0.6" w.c. to 0.8" w.c. is shown fo air conditioning purposes only.
6. At higher altitudes, a properly de-rated unit will have approximately the same temperature rise at a particular CFM, while the ESP at that CFM will be lower.
AMEH96
BLOWER PERFORMANCE DATA
0.6 0.7 0.8
CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM
T1 - YELLOW 1.5 726 48 670 53 617 57 553 64 490 72 429 378 336
T2 - RED 2.0 905 39 860 41 812 43 761 46 712 49 663 610 574
T3 - ORANGE 2.5 1121 31 1074 33 1039 34 998 35 959 37 923 882 839
T4 - BLUE 3.0 1274 28 1239 28 1199 29 1166 30 1129 31 1096 1059 1021
T5 - BLACK 3.0 1306 27 1261 28 1232 29 1195 29 1162 30 1132 1090 1057
T1 - YELLOW 1.5 714 80 667 79 604 87 548 96 484 109 422 367 325
T2 - RED 2.0 904 58 851 62 804 66 761 69 708 75 664 612 572
T3 - ORANGE 2.5 1125 47 1075 49 1045 51 999 53 956 55 921 877 839
T4 - BLUE 3.0 1312 40 1271 42 1228 43 1202 44 1165 45 1127 1087 1044
T5 - BLACK 3.5 1423 37 1386 38 1354 39 1321 40 1278 41 1210 1134 1032
T1 - YELLOW 3.0 1297 54 1253 56 1209 58 1161 61 1111 63 1067 1022 974
T2 - RED 3.5 1507 47 1455 48 1422 49 1377 51 1334 53 1296 1251 1195
T3 - ORANGE 4.0 1677 42 1637 43 1602 44 1562 45 1526 46 1484 1441 1324
T4 - BLUE 4.0 1879 37 1842 38 1800 39 1762 40 1700 41 1566 1437 1319
T5 - BLACK 5.0 2044 35 1967 36 1894 37 1795 39 1702 41 1578 1452 1320
T1 - YELLOW 3.0 1331 66 1275 69 1206 73 1145 77 1080 81 1021 953 889
T2 - RED 3.5 1512 58 1452 60 1392 63 1336 66 1279 69 1219 1175 1115
T3 - ORANGE 4.0 1713 51 1666 53 1614 57 1569 56 1513 58 1468 1414 1364
T4 - BLUE 4.0 1892 46 1845 48 1802 49 1752 50 1707 52 1656 1614 1577
T5 - BLACK 5.0 2080 42 2038 43 2005 44 1960 45 1920 46 1879 1843 1791
A
MEH960603BX*
(MED-HI)
A
MEH960805CX*
(MED-HI)
(CFM & TEMPERATURE RISE VS. EXTERNAL STATIC PRESSURE)
0.4 0.5
A
MEH960403BX*
(MED-HI)
A
MEH961005DX*
(MED-HI)
EXTERNAL STATIC PRESSURE (Inches Water Column)
Model
--------------
Heating Speed
As Shipped
0.3
Motor
Speed
Tons
A
C at
0.5"
ESP
0.1 0.2