Crestron electronic CHV-TSTATRF Thermostat User Manual


 
infiNET™ Thermostat Crestron CHV-TSTATRF
Setup Mode Parameters/Functions (Continued)
PARAMETER/
FUNCTION
CODE VALID VALUES
DEFAULT
VALUE
NOTES
Cool Anticipator CA 1 – 6 3
Lower setting results in more
frequent cycles and faster
response (tighter regulation).
Higher setting results in less
frequent cycles and slower
response (looser regulation).
The default value should suffice
in nearly all installations.
Heat pump Balance
Point
(will only appear for
Heat pump and Dual-
Fuel Heat pump
systems)
Hb
16 to 90 (for Fahrenheit)
or
-9 to 32 (for Celsius) or
Disabled (--)
--
Heat pump systems have
performance restrictions based
on outdoor temperature. This
setting is the minimum outdoor
temperature at which the heat
pump (or dual-fuel heat pump)
system will run.
Aux-Heat Balance
Point
(will only appear for
Heat pump type
systems)
Ab
16 to 90 (for Fahrenheit)
or
-9 to 32 (for Celsius) or
Disabled (--)
--
Aux heat operation is locked out
when outdoor temperature
exceeds the Aux Heat Balance
Point. Dual-fuel systems do not
allow both the heat pump and
the aux to run at the same time.
Interstage Differential
(will only appear for
Heat pump systems)
dF
05 to 80 (tenths of a
degree Fahrenheit),
adjustable in 5 tenths
degree increments or
05 to 45 (tenths of a
degree Celsius),
adjustable in 5 tenths
degree increments
20 (F) or
1 (C)
Heat pump systems can allow
both the heat pump and aux to
run at the same time. This sets
the ambient temperature
threshold to trigger aux heat in
addition to the heat pump.
Run Fan During Heat
Calls
HF
Enabled (Y) or Disabled
(no)
no
Most heat systems handle the
fan call if required. If the system
requires the thermostat to
control the fan during heat calls,
set this parameter to “Y”.
Changeover Outputs
(will only appear for
Heat-Cool systems)
co
Enabled (Y) or Disabled
(no)
no
Indicates the mode in which the
thermostat is operating. Will
automatically be engaged for
heat pump or dual-fuel heat
pump systems. If not required, it
should be disabled to extend
battery life.
(Continued on following page)