infiNET™ Thermostat Crestron CHV-TSTATRF
Installation
NOTE: Installers should have a strong working knowledge of HVAC systems.
Mounting the CVH-TSTATRF to the Wall
The location of the thermostat can affect its performance and efficiency. Install the
thermostat away from direct sunlight, drafts, doorways, skylights and windows. Also
make sure the thermostat is conveniently located for control access and setup and do
not mount on an exterior wall.
Thermostats should be mounted 60 inches (152.4 cm) above the finished floor
(HVAC industry standard).
The following tools/hardware are required for installation.
Standard single-gang electrical box, mounted horizontally (not supplied)
Phillips screwdriver (not supplied)
Two 1-inch pan head Phillips screws (supplied)
Two AA batteries (supplied)
Use the following procedure to install the CHV-TSTATRF in a standard, single-gang
electrical box (refer to illustration on the following page):
1. Separate thermostat front plate from back plate (you may need to exert force
when removing the front plate).
2. Turn HVAC system power OFF.
3. Feed HVAC wiring from the electrical box through the hole in the center of
the back plate so it can be connected to the proper terminals on the
CHV-TSTATRF after the thermostat is mounted.
4. Make sure unit is correctly oriented and place it in the electrical box.
CAUTION: Excess wire that is pinched between the CHV-TSTATRF and electrical
box could short out. Make sure that all excess wire is completely inside the electrical
box and not between the box and the CHV-TSTATRF.
NOTE: To ensure accurate temperature readings, avoid drafts in the back of the unit
by plugging the wire hole with insulation.
5. Attach the CHV-TSTATRF back plate to the electrical box using the
supplied two 1-in. pan head screws.
6. Attach faceplate.
7. Insert batteries and attach battery compartment cover.
8. Turn HVAC system power ON.
NOTE: Crestron has provided small slots on either side of the battery cover,
designed to allow a flathead screwdriver to be inserted to assist in removal.
8 infiNET™ Thermostat: CHV-TSTATRF Operations & Installation Guide – DOC. 6490