Crestron CHV-TSTATRF infiNET™ Thermostat
CHV-TSTATRF in Heat Only Application
Transformer
Heat
Relay
Optional, for power
R
C
System
120 VAC
(Refer to “Basic Thermostat
Setup” on page 15)
CHV-TSTATRF in Heat Only with Fan Application
Transformer
Heat
Relay
Optional, for power
R
C
System
120 VAC
Fan
Relay
RH-RC jumper required
since supply power is
returned through RH
(Refer to “Basic Thermostat
Setup” on page 15)
NOTE: To run fan during heat calls, be sure to enable the HF parameter by setting
it to “Y”. Refer to “Advanced Setup” which starts on page 18 for details.