Plug in the power cord to restore power after any required
maintenance.
The chiller control automatically performs its bootup routine.
When bootup is complete, the screen displays the To Process
temperature. The chiller is ready to run.
Press the Start Chiller button.
Check the Pump and Compressor lights on the control
panel; they should turn on and off as the pump and com-
pressor cycle on and off. The To Process temperature dis-
plays on the control. The To Process temperature is real-
time temperature. It should change as the chiller runs and
cools the fluid.
S
TARTING/
S
TOPPING THE
CHILLER
Series 1 Portable Chillers, TIC Control UGH016/0500
4-4
OPERATION
If you disconnect the Chiller
from the main power supply
and reconnect it, the Chiller
needs 15 minutes for the
crankcase heater to warm
up. You can not use the
Chiller during this time.
To safely stop the chiller at any time, press the red Stop
Chiller button on the control panel.
The chiller remains on, but stopped. The display screen on
the control remains on.
NOTE: When you press the Stop Chiller button, the pump and
compressor both stop. If you want to restart immediately by
pressing the Start Chiller button, the pump will turn on but the
compressor will not turn on for three minutes. The Process
Pump light on the control panel will light immediately. After
three minutes the compressor turns on and the Compressor
light on the control panel lights.