Burnham 8H Boiler User Manual


 
79
Item
No.
Description Part No. Size Quantity
5-8 Pilot Assembly and Piping -- Intermittent Ignition (Honeywell EI) Canada
5 - 10 Section, Natural Gas
5 - 7 Section, LP Gas
A
Pilot Burner, Honeywell Q348A1002, Natural Gas 8236072U 805H-810H
1
Pilot Burner, Honeywell Q348A1010, LP Gas 8236081 805H-807H
B Igniter/Sensor Cable, 36” Lg., Honeywell 394800-36 8236084
All 1
C Ground Wire Assembly 6136054
D Brass Compression Union, 1/4” OD Tube 8236008 805H-807H 1
E Shut-Off Valve, Essex P2L 822645
808H-810H 1F Pipe Tee, 1/8” NPT, Malleable 806601005
G Pipe Plug, 1/8” NPT, Sq. Head 806603508
H Brass Compression Adapter, 1/4” OD Tube x 1/8” NPT 822630
805H-807H Natural Gas 2
808H-810H Natural Gas 3
805H-807H LP Gas 1
J Solenoid Gas Valve, Johnson H91WG-6 822666
All
1K Junction Box, 4” Sq. x 1-1/2” Deep 8136259
L Rigid Conduit Nipple, 1/2” NPT x 1-1/2” Lg. 8136019
M Conduit Locknut, 1/2” 8136220 2
N Plastic Insulating Bushing, 1/2” 8136034 1
P Regulator, Maxitrol RV12LT, Natural Gas 8226005
805H-810H
Natural Gas Only
1