Burnham 8H Boiler User Manual


 
58
I. Check pilot burner ame and main burner ames
through observation port.
1. Check pilot ame. Refer to Table 11 for appropriate
pilot detail.
2. Adjust thermostat to highest setting.
3. Check main burner ames. See Figure 52. Flame
should have clearly dened inner cones with no
yellow tipping. Orange-yellow streaks caused
by dust should not be confused with true yellow
tipping.
Yellow-tipping indicates lack of primary air.
Improper burner alignment on Main Burner Orice
will also affect primary air injection. Adjust primary
air as follows:
Figure 49: Honeywell Q348 Pilot Flame
(24V Electronic Ignition)
Figure 48: Honeywell Q314 Pilot Flame
(24V Standing Pilot)
Figure 50: Honeywell Q179D Pilot Flame (OP)
Figure 51: Honeywell Q179C Pilot Flame (EP)
Figure 52: Main Burner Flame