Bosch Appliances ICP-CC404 Home Security System User Manual


 
ICP-CC404 | Installation Guide | 22.0 Programming Sheets
88 Bosch Security Systems, Inc. | 12/08 | F01U089401-02
Location
Function
Options/Notes
Default/
Programming Entry
267 to 322
Zone Definitions
Refer to page 54
2 0 0 1 14 1 1
(Delay 1)
12 0 0 1 12 1 1
(Fixed 24-hr burglary)
Zone #01
(267 to 273)
Zone #05
(295 to 301)
1 0 0 1 14 1 1
(Handover)
12 0 0 1 12 1 1
(Fixed 24-hr burglary)
Zone #02
(274 to 280)
Zone #06
(302 to 308)
1 0 0 1 14 1 1
(Handover)
13 0 0 1 12 1 1
(Fixed 24-hr fire)
Zone #03
(281 to 287)
Zone #07
(309 to 315)
0 0 0 1 14 1 1
(Instant)
9 0 0 1 12 1 1
(Fixed Tamper)
Zone #04
(288 to 294)
Zone #08
(316 to 322)
The first location (from the left) of the zone definition is the Zone Type. The options are:
0 Instant
1 Handover
2 Delay 1
3 Delay 2
4 Reserved
5 Reserved
6 24-hour medical
7 24-hour panic
8 24-hour hold-up
9 24-hour tamper
10 Reserved
11 Keyswitch
12 24-hour burglary
13 24-hour fire
14 Chime
15 Not used
The second location of the zone definition is the Zone Pulse Count. Use the pulse count to program the
number of pulses (0 to 15) that must register within the pulse count time to activate an alarm.
The third location (from the left) of the zone definition is the Zone Pulse Count Time. The options are:
20 ms Loop Response Time: 150 ms Loop Response Time:
0 0.5 sec
1 1 sec
2 2 sec
3 3 sec
4 4 sec
5 5 sec
6 10 sec
7 15 sec
8 20 sec
9 30 sec
10 40 sec
11 50 sec
12 60 sec
13 90 sec
14 120 sec
15 200 sec
The fourth location of the zone definition is the Zone Options 1 parameter. The options are:
1 Lockout siren/dialer
2 Delay Alarm Report
4 Silent alarm
8 Sensor watch
The fifth location of the zone definition is the Zone Options 2 parameter. The options are:
1 Isolated in STAY Mode 1
2 Zone isolation allowed
4 Forced arming allowed
8 Zone Restore Report allowed
The sixth location of the zone definition is the Report Code. The options are:
0 Do not send Zone Alarm Reports
1 Send Zone Alarm Reports
The seventh location of the zone definition is the Zone Dialer Options parameter. The options are:
0 No Zone Reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1
fails
The keyswitch zone options replace Zone Options 1 for zones programmed to operate as keyswitch
zones (Zone Type = 11). The options are:
0 Latching arm and disarm in AWAY Mode
1 Latching arm in AWAY Mode
2 Latching disarm from AWAY Mode or
STAY Mode
4 Latching arm and disarm in STAY Mode
5 Latching arm in STAY Mode
6 Latching disarm from STAY Mode
8 Momentary arm and disarm in AWAY
Mode
9 Momentary arm In AWAY Mode
10 Momentary disarm from AWAY Mode or
STAY Mode
12 Momentary arm and disarm in STAY Mode
13 Momentary arm in STAY Mode
14 Momentary disarm from STAY Mode