Bosch Appliances ICP-CC404 Home Security System User Manual


 
ICP-CC404 | Installation Guide | 1.0 Introduction
Bosch Security Systems, Inc. | 12/08 | F01U089401-02 7
1.0 Introduction
Congratulations on selecting the ICP-CC404 Control
Panel for your installation. Take the time to read
through this guide and familiarize yourself with the
outstanding operating and installation features of this
system so you can get the most from your unit.
In all aspects of planning, engineering, styling,
operation, convenience, and adaptability, we try to
anticipate your every possible requirement.
Programming simplicity and speed are major
considerations; we believe that our objectives are
more than satisfied.
This Installation Guide explains all aspects of
programming the ICP-CC404 Control Panel from
factory default to final commissioning. All system
parameters and options are detailed, but suitability is
left to the individual. You can tailor each control
panel to meet your requirements quickly and easily.
The programming simplicity makes your installation
quick, accurate, and rewarding.
As control panels continue to improve over the years,
they become very powerful. We have addressed the
needs of some early first-time users who have
advanced to true “power users,” while maintaining
the simplicity of the product and the Installation
Guide.
1.1 Features
The ICP-CC404 Security System uses the latest in
microprocessor technology to provide you with useful
features, and superior reliability and performance.
The control panel provides these features:
Eight programmable User Codes (1 to 8)
Eight remote radio User Codes (9 to 16)
Four programmable Burglary Zones
Four programmable 24-Hour Zones
Dual reporting
On-board Line Fault Module
Telco arming/disarming sequence
Automatic arming and disarming
Codepad Duress, Panic, Fire, and Medical
Alarms
STAY Mode and AWAY Mode operation
Upload/download programmable
Dynamic battery testing
Entry and Exit Warning beeper
Remote arming
Answering machine bypass
AC fail and system fault indicators
Monitored Siren Output
Strobe Output
Relay Output
Separate Fire Alarm sound
EDMSAT – Satellite Siren-compatible
Zone lockout
Sensor watch
Day Alarm
Walk Test Mode
Delayed reporting
40 events in non-volatile memory
1.2 Quick Start
The following steps allow you to use the ICP-CC404
Control Panel with factory default values. The default
values allow the control panel to communicate in the
Contact ID format. If you are not familiar with
programming the range of control panels, read the
information in Section 2.0 Programming on page 9
before starting the installation.
1. After all wiring is complete, connect the AC plug
pack to the control panel.
Both the MAINS and AWAY indicators light.
The MAINS indicator lights to indicate that the
AC MAINS supply is connected. The AWAY
indicator lights to indicate that the system is
armed in AWAY Mode.
If any 24-Hour zones are unsealed when you
power up the system, the Siren, Strobe, and Bell
Outputs activate into alarm and the
corresponding zone indicators flash.
2. Enter the default Master Code (2580) and press
[AWAY] to disarm the system and to reset any
alarm that occurred when you powered up the
system.
The AWAY indicator turns off to signify that the
system is disarmed.
If any zone indicator flashes, an alarm occurred
in that zone.
If a zone indicator lights constantly, the zone is
unsealed.
3. Connect the backup battery.
4. Enter the default Master Code (2580) and press
[AWAY].
Two beeps sound and the STAY and AWAY
indicators flash simultaneously to indicate you
entered Installer’s Programming Mode. You are
automatically positioned at Location 000, the first
digit of the Primary Telephone Number for
Receiver 1.
5. Enter the default Installer Code (1234) and press
Enter the Primary Telephone Number, the
Secondary Telephone Number, and the
Subscriber ID Number for Receiver 1.
Refer to Sections 11.1 on page 46, 11.2 on
page 47, and 11.5 on page 47 for more
information about programming these numbers.