Bosch Appliances ICP-CC404 Home Security System User Manual


 
ICP-CC404 | Installation Guide | 11.0 Dialer Information
Bosch Security Systems, Inc. | 12/08 | F01U089401-02 47
When Receivers 1 or 2 is set up for
domestic reporting, telephone numbers
programmed into these locations are
ignored. Refer to Section 6.1.2
Changing Domestic Phone Numbers on
page 28 (using the Installer Code
function) or Section 6.2.3 Changing
Domestic Phone Numbers on page 33
(using the Master Code Function).
11.2 Secondary Telephone Number for
Receiver 1 and Receiver 2
Program the Secondary Telephone Number for
Receiver 1 in Locations 016 to 031.
Program the Primary Telephone Number for
Receiver 2 in Locations 056 to 071.
The default value for both telephone numbers is
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.
Refer to Section 11.1 Primary Telephone Number for
Receiver 1 and Receiver 2 on page 46 for programming
information.
When Receivers 1 or 2 are set up for
domestic reporting, telephone numbers
programmed into these locations are
ignored. Refer to Section 6.1.2
Changing Domestic Phone Numbers on
page 28 (using the Installer Code
function) or Section 6.2.3 Changing
Domestic Phone Numbers on page 33
(using the Master Code Function).
11.3 Handshake Tone for Receiver 1 and
Receiver 2
Program the Handshake Tone for Receiver 1 in
Location 032.
Program the Handshake Tone for Receiver 2 in
Location 072.
The default value for both Handshake Tones is 1.
These locations set the type of handshake tone
required for the receivers before data transmissions to
the monitoring station begin. The options are:
1 – HI LO Handshake
HI LO Handshake Tone is required to communicate
in Contact ID Format or High Speed DTMF.
2 – 1400 Hz
1400 Hz Handshake Tone is required to
communicate in Ademco Lo Speed Format or
Domestic Dialing Format.
3 – 2300 Hz
Reserved.
4 – No Handshake
Setting these locations to No Handshake Tone is not
recommended.
5 – Pager
Pager Handshake Tone is required to communicate in
Basic Pager Format.
11.4 Transmission Format for Receiver 1
and Receiver 2
Program the Transmission Format for Receiver 1 in
Location 033.
Program the Transmission Format for Receiver 2 in
Location 073.
The default value for both Transmission Formats is 1.
These locations select the data format used to send
reports to the base station receiver. These locations
also allow you to configure the control panel for
domestic or basic pager formats. The options are:
1 – Contact ID
2 – 4 + 2 express
3 – FSK 300 baud Bell
4 – Domestic
5 – Basic Pager
7 – Reserved
The Basic Pager option supports only
eight zones due to protocol limitations. If
you use more than eight zones, this
option is not recommended.
If you use the Zone 16, the 4+2 Express
and FSK 300 Baud formats are not
recommended because Zone 16 will be
assigned as "0" and some receivers will
not support this zone.
11.5 Subscriber ID Number for Receiver
1 and Receiver 2
Program the Subscriber ID Number for Receiver 1 in
Locations 034 to 039.
Program the Subscriber ID Number for Receiver 2 in
Locations 074 to 079.
The default value for both Subscriber ID Numbers is
0 0 0 0 0 0.
The Subscriber ID Number is sent to identify the
calling control panel.
For Basic Pager Format, Locations 034 to 036 (for
Receiver 1) and Locations 074 to 076 (for Receiver 2)
are ignored and the first digit of the Subscriber ID
Number must start in Location 037 (Receiver 1) and
Location 077 (Receiver 2).