3.0 Codepad Indicators
3.1 ICP-CP508W Eight Zone LED
Codepad
Figure 1: ICP-CP508W Eight Zone LED
Codepad
The codepad is the communications interface
between you and the alarm system. The codepad
allows you to issue commands and offers visual and
audible indications to guide you through general
operation.
The codepad incorporates a number of indicators:
eight zone indicators show the condition of each zone
and four other indicators show general status. These
indicators are described in Table 8 through Table 13
on page 17.
Zone Indicators
Table 8: Zone Indicators
Indicator Definition
On The zone is unsealed
Off The zone is sealed
Flashing fast
(0.25 sec on/0.25 sec off)
The zone is in alarm
Flashing slow
(1 sec on/1 sec off)
The zone is manually
isolated
STAY Indicator
The STAY indicator lights when the system is armed
in STAY Mode 1 or STAY Mode 2. The STAY
indicator flashes with the AWAY indicator when you
are in Installer’s Programming Mode or you are using
a Master Code function.
For more information, refer to:
Section 4.3 on page 19 to arm the system in STAY
Mode 1.
Section 14.3.4 on page 57 to set zones to
automatically isolate in STAY Mode 1.
Section 4.5 on page 20 to arm the system in STAY
Mode 2.
Section 6.1.4 on page 30 to use the Installer Code
to set zones to automatically isolate in STAY
Mode 2.
Section 6.2.5 on page 35 to use the Master Code
to set zones to automatically isolate in STAY
Mode 2.
Table 9: STAY Indicator
Indicator Definition
On The system is armed in STAY Mode 1 or
STAY Mode 2
Off The system is not armed in STAY Mode 1 or
STAY Mode 2
Flashing Zone Isolating Mode or setting STAY Mode 2
zones
AWAY Indicator
The AWAY indicator lights when the system is
armed in AWAY Mode. The AWAY indicator flashes
with the STAY indicator when you are in Installer’s
Programming Mode or you are using a Master Code
function.
Refer to Section 4.1 Arming the System in AWAY Mode
on page 18 for more information.
Table 10: AWAY Indicator
Indicator Definition
On The system is armed in AWAY Mode
Off The system is not armed in AWAY Mode
MAINS Indicator
The MAINS indicator shows whether the system’s
AC MAINS supply is normal or failed.
When programming in Installer’s Programming
Mode or using a Master Code function, the MAINS
indicator lights to indicate a location value from 10
to 15. The MAINS indicator represents the 10 digit,
which is added to the value of the lit zone indicator
(for example, if the value programmed in a location
is 12, the MAINS and Zone 2 indicators light).
Table 11: MAINS Indicator
Indicator Definition
On The AC MAINS power is normal
Flashing The AC MAINS supply failed
FAULT Indicator
The FAULT indicator lights when the system detects
a system fault. Refer to Section 4.12 Fault Analysis Mode
on page 22 for more information on system faults.
Each time a new system fault is detected (the FAULT
indicator flashes), the codepad beeps once per
minute.
Press [AWAY] to stop the beeping and to
acknowledge the fault.