Bosch Appliances D1265 Home Security System User Manual


 
D1265 | Owner's Manual | Part II: System Commands
24 Bosch Security Systems, Inc. | 9/10 | F01U169130-02
If there are no events to view, There are
currently no events in memory
shows.
6. You can return to idle text at any time by
pressing Exit button.
Walk Test (CMD + 4 + 4)
Description
Use this function to test keypads, detection devices,
and sounders (both interior and exterior) to be certain
they function properly. You can review untested points
at your keypad to help pinpoint any problems.
You cannot arm your system while in the walk test
mode, and no alarm reports are sent to your security
company unless a 24-hour point is activated (such as
fire or panic). A Walk Test Start Report might be
programmed to be sent to your security company.
Upon initiation, the walk test tests the burglary bell
pattern on the bell output and ring the keypad
burglary bell for 2 sec. The AC is disabled for 4
minutes in order to test the system’s battery power. If
the battery cannot maintain the system for the 4-
minute period, the keypad appears to power off. If
your keypads are programmed to be supervised, the
main alarm panel piezo intermittently during this 4-
minute period. If this happens, contact your security
company. At the end of the 4-minute period, AC is
returned to the system and the control panel restores.
To test individual detection devices, simply activate
sensors and open protected doors and windows one-at-
a-time. As each detection device is faulted, the keypad
emits a brief tone and the display indicates for 60 sec
that the point has been tested. This verifies that each
detection device is working properly.
Using Walk Test
1. Ensure the display shows disarmed idle text.
2. Press the CMD button. The display shows
*System Command*.
3. Press the 4 button and then the 4 button.
If you prefer, you might use the function
list in place of Steps 2 and 3 to initiate
this function.
Press the Menu button to enter the
function list.
Press the Next button repeatedly.
When you reach the Walk Test button,
press it.
4. The burglary bell sounds for 2 sec. When the
display shows ### points remain to be tested
(### is the number of points) you can begin.
Test each point by first opening and then closing
the door or window, or activating the other
detection device types.
Check the display after testing each point. For
interior points, walking past the device once is
sufficient. If any point will not test correctly,
contact your security company for service.
5. During the Walk Test you might want to refer to
the points that remain untested by pressing the
View untested pts button.
The display shows ### pts untested.
Press the Next Pt or Prev Pt
buttons to refer to
information about specific points that have not
yet been tested.