Bosch Appliances D1265 Home Security System User Manual


 
D1265 | Owner's Manual | Part II: System Commands
Bosch Security Systems, Inc. | 9/10 | F01U169130-02 21
Master Arm Instant (CMD + 1 + 1)
Use this function to turn on a single area, both
perimeter and interior without delays. When entering
CMD 11, remember that the second 1 must be pressed
within 2 sec after pressing the first 1.
The menu entry Master Arm Inst is different in that it
allows all or selected areas to be armed instantly.
CMD 11 does not comply with SIA CP-01
Standard.
Using the CMD + 1 + 1 command only
instantly arms the area where the keypad
has been assigned. For example, if the
D1265 is assigned to Area 1, only Area 1
is armed when CMD + 1 + 1 is pressed.
1. Ensure your keypad shows idle text.
2. Press the CMD button. The display shows
*System Command*.
3. Press the 1 button. Now press the 1 button
again.
The keypad display shows All On Instant.
4. To disarm your security system, enter your
personal passcode and press ENTER.
Perimeter Instant (CMD + 2)
Turn On the Perimeter With No Delays
Description
Use this function to turn on only the perimeter of your
building, leaving the interior of the building disarmed.
This function allows no exit or entry delay time
through the perimeter, including the designated exit
delay door.
This function is useful in residential systems when
everyone is home and ready to retire for the evening.
You can have the security of an armed perimeter, yet
move freely throughout the interior of the premises.
It is also useful in commercial systems when you are
working before or after business hours and wish to
have the perimeter armed. Remember there are no
entry or exit delays when you use this function. You
must disarm (turn off) the system to enter or exit the
premises.
Using Perimeter Instant
Interior points are not armed with this command and
might remain faulted while arming with CMD 2.
1. Press the CMD button.
2. The display shows *System Command*.
3. Press the 2 button.
If you prefer, you might use the function
list in place of Steps 1 through 3 to
initiate this function.
Press the Menu button to enter the
function list.
Press the Next button repeatedly.
When you reach the Perimeter Arm
Inst button, press it.