Toshiba RAV-SM1404UT-E Air Conditioner User Manual


 
– 23 –
<Twin type>
: IEC standard
Indoor unit 1 RAV-SM 564SDT-E 564SDT-E
Model Indoor unit 2 RAV-SM 564SDT-E 564SDT-E
Outdoor unit RAV-SP 1104AT(Z)(ZG)-E 1102AT(Z)(ZG)-E
Cooling capacity (kW) 10.0 10.0
Heating capacity (kW) 11.2 11.2
Indoor unit
Power supply 1 phase 230V (220 – 240V) 50Hz
Running current (A) 12.98 –11.90 11.72 – 10.74
Power consumption (kW) 2.77 2.50
Cooling Power factor (%) 97 97
EER 3.61 4.00
Electrical
Energy efficiency class AA
characteristics
Running current (A) 12.51 – 11.47 11.95 – 10.95
Power consumption (kW) 2.67 2.55
Heating Power factor (%) 97 97
COP 4.19 4.39
Energy efficiency class AA
Fan Centrifugal
Fan unit Standard air flow H/M/L (m³/min.) 13.0 / 11.3 / 9.7 13.0 / 11.3 / 9.7
Motor (W) 60 60
Sound pressure level
Under air inlet H/M/L (dB•A) 45 / 40 / 36 45 / 40 / 36
Back air inlet H/M/L (dB•A) 33 / 31 / 28 33 / 31 / 28
Sound power level
Under air inlet H/M/L (dB•A) 60 / 55 / 51 60 / 55 / 51
Back air inlet H/M/L (dB•A) 48 / 46 / 43 48 / 46 / 43
Outdoor unit
Power supply 1 phase 230V (220 – 240V) 50Hz
Standard length (m) 7.5 7.5
Min. length (m) 3 5
Refrigerant pipe
Max. total length (m) 50 50
Refrigerant charging amount (Charge-less up to 30m)
40g/m (31m to 50m)
Height difference
Outdoor lower (m) 30 30
Outdoor higher (m) 30 30
Fan Propeller fan
Fan unit Standard air flow volume (m³/min.) 101 125
Motor (W) 100 + 100 63 + 63
Gas side
Main (mm) 15.9 15.9
Connecting pipe
Sub (mm) 12.7 12.7
Liquid side
Main (mm) 9.5 9.5
Sub (mm) 6.4 6.4
Sound pressure level Cooling/Heating (dB•A) 49 / 50 49 / 51
Sound power level Cooling/Heating (dB•A) 66 / 67 66 / 68
Revised 2: Jun., 2008