– 210 –
Positioning extrusion
PMV body
Concavity
PMV coil
Minus screwdriver
Front cabinet
Hooking claw
Front cabinet
Fan guard
No.
9
10
Part name
Pulse Motor Valve
(PMV) coil
Fan guard
Procedure
1. Detachment
1) Perform works of items
1
and
2
.
2) Release the coil from the concavity by
turning it, and remove coil from the PMV.
2. Attachment
1) Put the coil deep into the bottom position.
2) Fix the coil firmly by turning it to the
concavity.
1. Detachment
1) Perform works of items 1 of
1
and
2
.
2) Remove the front cabinet, and put it down
so that fan guard side directs downward.
XCAUTIONX
Perform works on a corrugated cardboard,
cloth, etc. to prevent flaw on the product.
3) Remove the hooking claws by pushing
with minus screwdriver along with the
arrow mark in the right figure, and remove
the fan guard.
2. Attachment
1) Insert claws of the fan guard in the hole of
the front cabinet. Push the hooking claws
(10 positions) with hands and then fix the
claws.
XCAUTIONX
All the attaching works have completed.
Check that all the hooking claws are fixed
to the specified positions.
Remarks