Toshiba RAV-SM1404UT-E Air Conditioner User Manual


 
153
The swing mode selection (DN code No. [F0]), louver fix (DN code No. [F1] to [F4]) and restriction ratio setting for
save operation (DN code No. [C2]) can be set/changed from the normal DN setup (Detail DN setup).
DN
42
45
C2
CC
CD
D0
D1
D3
D4
F0
F1
F2
F3
F4
Item
Self-clean operation time
Selection of louver horizontal discharge
position
Current demand X% to outdoor unit
Setting of self-clean operation forced stop
Clean operation stop function when
[ON/OFF] operation is prohibited.
Existence of remote controller save function
Existence of 8°C heating operation function
Revolution frequency of self clean operation
Display / No display of
[Dry operation] during self clean operation
Louver swing mode
Louver No.1 fixed position
Louver No.2 fixed position
Louver No.3 fixed position
Louver No.4 fixed position
Contents
0000: None 0000: 0.5 h to 0.012: 0 h
Set when compressor-ON time is 10 to 60 minutes.
When ON-time is 60 minutes or more,
the double of this operation time setting is set.
0000: Smudging-less setting
0002: Cold draft preventive setting
0050: 50% to 0100: 100%
0000: No
Clean operation is performed in case of stop by HA input.
HA operation output OFF during clean operation in case of
stop by remote controller
0001: Yes
Clean operation is not performed in case of stop by HA input.
HA operation output ON during clean operation in case of stop
by remote controller
The air conditioner stops (including fire alarm such as remote
monitor system) while setup of [ON/OFF] operation prohibited
(Central 1, 2) is performed from the central controller side.
0000: Valid (Clean operation)
0001: Invalid (No clean operation)
0000: Invalid (Impossible) 0001: Valid (Possible)
0000: Invalid (Impossible) 0001: Valid (Possible)
0000: Invalid (Self clean operation is not carried out.)
0001: Valid (Self clean operation is practiced with 210 rpm.)
0000: Display 0001: No display
0000: No synchronization 0001: 4-way synchronization
0002: Dual 0003: Cycle
0000: Release (Free)
0001 to 0005: Horizontal discharge position to
Downward discharge position
0000: Release (Free)
0001 to 0005: Horizontal discharge position to
Downward discharge position
0000: Release (Free)
0001 to 0005: Horizontal discharge position to
Downward discharge position
0000: Release (Free)
0001 to 0005: Horizontal discharge position to
Downward discharge position
At shipment from factory
0002: 1 hour
0000: Smudging-
less setting
0075: 75%
0000: None
0000: Valid
0001: Valid (Possible)
0001: Invalid (Impossible)
0001: Valid
(210 rpm / operation)
0000: Display
0001: 4-way
synchronization
0000: Release
0000: Release
0000: Release
0000: Release