Tamron TS690R Smoke Alarm User Manual


 
Part-Set Application Example
This application example shows how to configure
the part set buttons to set different areas of a 3
bedroom house.
Using the drawing of a typical 3 bedroom house,
the following part set modes are required:
Part Set A Circuits 01 through to 08 armed
and circuits 09 and 10 omitted.
Part Set B Circuits 01 through to 09 armed
and circuit 10 omitted.
Part Set C Circuits 01 through to 06 armed
and circuits 07 through to 10
omitted.
1. First create a table listing the circuits that are
required to be armed (A) and omitted (O) for
each part set mode:
Circuit Location P-Set A P-Set B P-Set C
01 Front Door A A A
02 Hallway d detector A A A
03 Hall door to garage A A A
04 Garage door A A A
05 Garage back door A A A
06 Kitchen door A A A
07 Dinning room PIR A A O
08 Lounge PIR A A O
09 Bedroom 2 PIR O A O
10 Landing PIR O O O
2. From the above table, program circuits 01-10
as omitted or armed for each part set mode
(see “Configure Part Sets on page 38).
Circuit 02 (Hallway detector) must be
programmed as a "Night" circuit with the
"Entry" attribute. This will ensure that the
en try time r i s s tart ed wh en t he
occupants come downstairs to unset the
system.
42
Appendices TS690R Installation Manual
Enter user type:
= Master
= Standard
= Holiday
4
1
2
3
Enter user No.
e.g. 04
Enter master user (5678)
= PA Code
7
e.g. 1 for Master
Enter New passcode
e.g. 2589
= Set Only
4
= Reset Only
5
= Duress
6
USER 1-
USER 2-
USER --
STANDARD
NEW ----
NEW 2589
Setup New Users Flowchart