Tamron TS690R Smoke Alarm User Manual


 
Do
l
Make sure there is less than 10mm between
the magnet and transmitter body with the
door or window closed.
l
Make sure the arrow on the magnet aligns with
the mark moulded into the side of the case
with the door/ window closed.
Do NOT mount the unit
l
On the hinged edge of the door..
l
Near the floor.
l Close to or on large metal structures.
l Closer than one metre to mains wiring and
metal water or gas pipes.
l Inside steel closures.
l
Next to electronic equipment, particularly
computers, photocopies or other radio
equipment.
Using the internal Reed Switch
If you plan to use the internal reed switch the YOU
MUST CUT THE INTERNAL REED SHUNT LINK. However,
if at a later date you wish to connect hard wired
contacts you must re-solder the link.
Installation
1. Open the transmitter by inserting a small flat
bladed screwdriver in the slot at the bottom of
the case.
2. Install two "AAA" size alkaline batteries (not
supplied). Do not use rechargeable (Nickel
Cadmium) batteries, because they are 1.2V
and not 1.5V.
3. Learn the detector (see "Adding Devices" on
page 33).
4. Mount the transmitter back box in its required
position using two type "C" 15mm domehead
screws.
5. Make sure the back is flush against the surface
and pushes the tamper bar in far enough to
activate the tamper switch.
6. Fit the body of the transmitter to the back box.
Connecting External Door Contacts
You can wire external normally closed devices to
the 535r universal transmitter. You can connect
several contacts in series, but the control panel will
treat them all as one zone. Do not use more than
10 metres total cable length from the 535r to the
last external contact.
1. Remove the wire links from the terminal
connector.
2. Connect the normally closed contacts as
shown:
3. Make sure the internal reed shunt link is intact.
DO NOT CUT.
If you remove the external contacts at a later
date, make sure you replace the wire links on the
alarm and tamper terminals.
Testing
1. Put the TS690R control panel into walk test
mode (user code + [ENT] + [2]).
2. Hold The detector in place.
3. Trigger the tamper.
4. Make sure the control panel receives an
alarm.
5. Choose another site for the detector if the
panel does not receive the signal.
6. Press [ESC] twice when you have finished
testing, to put the control panel back in the
open mode.
18
System Installation TS690R Installation Manual
Tamper
circuit
Alarm
circuit
6
5
4
3