TS690R Installation Manual System Installation
Section Option Default
User Codes User 00 Engineer 1234
User 01 Master 5678
User 02 - 10 Not Used
Panel
Outputs
Panel Output 1 Walk Test
Panel Output 2 Courtesy Light
Panel Output 3 SW12V
Panel Output 5 Code Accepted
Panel Output 6 Code Accepted
Panel Output 7 Code Accepted
Panel Output 8 Code Accepted
Circuits Circuits 01 - 38 Not Used
System Timers
00 2nd Alarm Time 005 seconds
01 No of Re-arms 003
02 Settle Time 005 seconds
03 Part Set Coms Dly 030 seconds
04 Exit Time 030 seconds
05 Entry Time 015 seconds
06 Bell Duration 020 minutes
07 Bell Delay 000 minutes
08 D-Knock Delay 008 seconds
09 Test Time 014 days
10 Second Entry 015 seconds
11 Abort Delay 180 seconds
12 Monitor Duration 010 seconds
13 Part Set Bell Delay 030 seconds
14 Courtesy Duration 060 seconds
15 AC Off Delay 000
Section Option Default
Setting
Modes
Full Set Final Exit Setting
Part Set A Timed Exit
Part Set B Timed Exit
Part Set C Timed Exit
Rem Reset Algorithm 004
Configuration
00 Bell is an SAB Yes
01 User 1 Limited No
02 Fire Signals All Yes
03 Silent 24hr Circuits No
04 Enable Duress No
05 Invert Abort No
06 Monitor Polling Sig No
07 User Reset No
08 Fob unset with entry Yes
09 Passcode + ENT No
10 Loud Chime Tones Yes
11 Do Battery Test No
12 Final Exit is Night No
13 Mimic Alms & Flts No
14 Invert panel outputs No
15 Set with AC off No
16 Tampers user reset No
17 Enable jamming Yes