Log Event Codes
Display Description
AC OFF
Mains power removed
AC ON
Mains power restored
ALARM 01-38
Full alarm from circuit 01-38
AUX 01-38
Auxiliary alarm from circuit 01-38
AUX TAMP
Auxiliary tamper alarm
BATT FLT
Battery fault (voltage below 10.5V)
BELL TST
Bell test performed
C TMP 01-04
Code tamper from keypad 01-04
CCT ISOL
24hr circuits isolated
DATE CHG
System date changed
DEFL T 01
User 01 reset to 5678 by the engineer
DURS 01-10
Duress alarm from user 01-10
E ALM 01-38
Entry time-out alarm from circuit 01-38
ENTRY 01-38
Entry timer started by circuit 01-38
FACT RST
System “Factory Restarted”
FIRE 01-38
Fire alarm from circuit 01-38
FIRST 01-56
The first activation of a D-Knock circuit
FOB 01-38
525r remote setting device operated
FULL SET
System full set
JAMMED
System jammed by another radio source
KEYSW 01-38
Key point operation from circuit 01-38
LID TAMP
Control panel lid removed
NO EVENT
No log event
OMIT 01-38
Circuits 01-38 omitted
OMIT REM
All omitted circuits reinstated
OMITR 01-38
Circuit 01-38 reinstated
P/SET A/B/C
System part set A, B, or C
PAALM 01-38
Panic alarm from circuit 01-38
PANIC 01-10
Panic alarm from user 01-10
R ADD 0 1-04
Remote keypad added to the system
R REM 01-0 4
Remote keypad removed from system
R TMP 01-04
Remote keypad tamper
REARMED
System re-armed all healthy circuits
REM RST
System reset by “Remote Reset” code
SET FAIL
System failed to Set
SITE RST
System “On-Site” restart
SYS OPEN
System fully unset
TAMP 01-38
Tamper alarm from circuit 01-38
TC OFF
All circuits taken off “Test”
TESTD 01-38
Number of circuits tested duringa walk test
T FAIL 01-38
Circuit failed during “Test”
TIME CHG
System time changed
USER 00-10
User code entered 00-10
WALK TST
System “Walk Test” selected
Reset User Code 1 [2.0]
This option allows the installation engineer to reset
the master user (user 01) back to the factory
default code of “5678". This feature is useful when
the master user has forgotten their passcode or
has accidentally changed it without realising. This
operation is logged.
39
TS690R Installation Manual Engineer's Menu 2
to reset user 1
0
E / MENU 2
RST USR 1
Reset User Code Flowchart