Tamron TS690R Smoke Alarm User Manual


 
Do mount the unit
l
Between 2 and 2.5 metres high for the best
general coverage in an average room.
Do NOT mount the unit
l
Facing a fire, boiler or window.
l
Over a radiator.
l
Near the floor.
l
Close to or on large metal structures.
l
Closer than one metre to mains wiring and
metal water or gas pipes.
l
Inside steel closures.
l
Next to electronic equipment, particularly
computers, photocopies or other radio
equipment.
l
Closer than 3 cm to a ceiling (to allow space
for dismounting the unit in the future).
Installation
1. Open the detector by inserting a small flat
bladed screwdriver in the slot at the bottom of
the case.
2. Install two "AAA" size alkaline batteries (not
supplied). Do not use rechargeable (Nickel
Cadmium) batteries, because they are 1.2V
and not 1.5V.
3. Learn the detector (see "Adding Devices" on
page 33).
4. Mount the detector back box in its required
position using two 16mm countersunk head
screws.
5. Clip the body of the detector to the back box.
Testing
1. Put the TS690R control panel into walk test
mode (user code + [ENT] + [2]).
2. Open and close the tamper for each PIR, this
will put the detector in test mode.
After opening and closing the tamper,
the detector remains in test mode for 30
minutes. In this mode the detector has a
30 seconds lockout time. At the end of
the 30 minutes the detector reverts to
normal mode, with a 3 minute lockout
time.
3. Make sure the control panel receives the
alarm from each detector.
4. Choose another site for the detector if the
panel does not receive the signal.
5. Wait 30 seconds with no movement in front of
the detector before triggering it again.
6. Press [ESC] twice when you have finished
testing, to put the control panel back in the
open mode.
Walk Testing and Lockout
In normal use the 515r uses a three minute lockout
timer in order to extend battery life. The lockout
timer operates as follows:
1. The unit detects movement, signals the control
panel, and starts the lockout timer.
2. If the unit detects movement while the lockout
timer is running, then it restarts the lockout timer
but DOES NOT signal the control panel.
3. When the lockout timer expires the unit signals
the control panel the next time it detects
movement.
If you want to test a 515r PIR in normal uses you
must wait at least 3 minutes between activations.
To make testing easier the detector changes the
lockout period to 30 seconds for the first 30
minutes after you put the batteries in or after you
trigger its tamper.
16
System Installation TS690R Installation Manual