Tamron TS690R Smoke Alarm User Manual


 
2. Press [A] to select the add/cancel devices
option.
3. Press [C] to remove an existing device.
4. The display will prompt you to enter the device
number (01 - 30). Enter the device number
and press [ENT]. The control panel will give a
rising multi-tone sound.
5. If required, repeat from step 3 for other devices
or press [ESC] to leave this programming
option.
Re-Map Keypad Circuits
This option allows the engineer to re-map the
remote keypad circuits. By default all wirefree
devices are allocated to circuits 01 - 30 and
remote keypad circuits are allocated to circuits 31
- 38. Using this option it is possible to re-map the
remote keypad circuits to circuits 01 - 30. For
example if your system of only uses 10 wirefree
detectors and one remote keypad, you can
re-map circuits 31 and 32 (remote keypad 1) to
circuits 11 and 12 so that the circuit numbering
remains sequential.
Wirefree detectors cannot be mapped to
circuits 31 to 38. To re-map a wirefree
detector it must be cancelled from the
system and then relearnt to a new device
number.
34
Engineer’s Menu 1 TS690R Installation Manual
Enter device No (31 - 38)
e.g. 31
The display shows the
current mapping.
Enter new circuit No.
e.g. 11
C
E / MENU 1
MAP? --
MAP? 31
TO 11
Re-Map Keypad Circuits Flowchart
Enter the device
number 01 - 30.
A
= Cancel devices
C
E / MENU 1
AD D / CANX
DEV ? --
Cancel Devices Flowchart