Configure Part Sets [2.8]
The TS690R can be configured to have up to three
parts set modes (Part Set A, Part Set B and Part Set
C). This option allows the engineer to configure
each part set mode. Within each part set mode
you must designate which circuits will remain
armed and which circuits will be omitted. When
the user selects the relevant part set mode the
system only arm the circuits that are designated as
armed and isolate the circuits that are designated
as omitted.
Only the circuit types “Night”, “Final Exit” and “Exit
terminator” can be designated as omitted.
If the system uses a 525r remote setting
device the "NIGHT" button is always
assigned to "Part Set A".
View System Log [2.9]
The engineer can use this option to view the
system log. The [A] and [C] keys allow you to scroll
backwards and forwards through the log events.
38
Engineer's Menu 2 TS690R Installation Manual
Select part set mode:.
e.g. Press B
= Next circuit
8
A
= Alternate Armed/Omitted
B
= Previous circuit
C
= Part set A
A
= Part set B
B
= Part set C
C
E / MENU 2
P / SET A
01 - ARMED
01 - OMIT
Repeat for remaining circuits
Configure Omits Flowchart
= Scroll backwards
9
A
= Alternate event, time & date
B
= Scroll backwards
A
= Scroll forwards
C
E / MENU 2
USER 00
ALARM 03
= Scroll forwards
C
View System Log Flowchart