Rinnai RCE-560PTR Fan User Manual


 
Convector 460/560PTR - 3 - ©Rinnai
Air Purifier Specification
Air Purifier Filter method (initial efficiency approx. 80%)
Anti-bacteria Activated Carbon (initial efficiency approx. 75%)
Operation Push button
Operation Changeover Automatic Operation (High/Med/Low) and Manual
Operation (Boost/High/Med/Low)
OFF Timer 3 step changeover (1, 2, 4 hour)
Louvre Location Top of appliance
Airflow (m
3
/min)
Boost 3.3, Hi 2.2, Med 1.8, Lo 1.4
Air Purifier Fan
Sirocco Fan 160 x 80L
Air Purifier Fan Motor Condensor line 4 pole motor
Dust Sensor Particle Counter (scattered light method)
Filter Replacement Indicator Calculated as on page 18
Safety Devices
Incomplete Combustion Device Thermocouple method
Flame Failure Thermocouple method
Reverse Flame Device
Bi-metal method OFF 150 5 C ON 125 10 C
Overheat Device Thermistor
level 4~12 70 C
level 1~ 3 70 C
Thermal fuse
216
C
OFF
Power Failure Device Within PCB unit
Tilt Switch Device Steel Ball Method (within PCB unit)
Over-current Protection 3-amp fuse
Loose Primary Filter Detection Device Micro-switch
Other
Available gas types NG, LPG
Electrical Frequency Converter 50Hz only
Replacement Filter HEOT - 003
φ
± ° ± °
°
°
°