Rinnai RCE-560PTR Fan User Manual


 
Convector 460/560PTR - 20 - ©Rinnai
Sensor Specification
“Drop Out” = Time until the gas is cut off after flame failure.
Sensing voltage varies depending on gas type. (Refer to combustion specifications)
Overheat Switches
If the air filter or air outlet becomes blocked, the overheat switch causes the solenoid valve to close
and operation to stop. The appliance can be re-lit when it has cooled. If the air filter or outlet
becomes blocked and the OHS fails, the thermal fuse will “blow”, causing the solenoid valve to close
and operation to stop. This is a “one-shot” fuse; therefore the appliance cannot be restarted until this
fuse has been replaced.
Reverse Flame Detection Device
Tilt Switch Safety Device
Normally, the tilt circuit is open, but the steel ball rolls when the unit is tilted, closing the circuit.
Ignition Sensing
Vo lt ag e ( mV )
ODS Sensing Voltage
(mV)
Thermocouple Output Drop Out
Time (sec)
Output at initial
check +2
NG: level 4~12
14
level 1~3 14
LPG: level 4~12
16
level 1~3 16
NG: >18mV
LPG: >20mV
<35mV
Below 60
NG: >18mV
LPG: >20mV
<35mV
OHS Type Characteristics
Thermistor
level 4~12
1~3
Operates at
70 C
Thermal Fuse Cut Off Temp
216
C
Type Characteristics
Reserve Flame
Detection Switch
(Bi-metal)
Operational
Te m p .
150 5
C OFF
Reset Temp.
125 10
C ON
Steel Ball Tilt Switch Activating Angle
50
° ~ 80°
1.5±
1.5±
1.5±
1.5±
°
±
0
10
°
± °
± °