Rinnai RCE-560PTR Fan User Manual


 
Convector 460/560PTR - 39 - ©Rinnai
)DXOW$QDO\VLV
Note: Before carrying out resistance checks, disconnect power.
$ $IWHUSUHVVLQJWKH+HDWHU212))EXWWRQ
a. the convection fan does not begin to rotate.
b. the solenoid valves do not open.
c. there is no spark.
Is there electrical supply?
YES
1. Confirm the connection at the wall socket.
2. Is the 3 amp fuse blown?
a. The sequence does not continue.
1. Broken wiring or loose pin connectors. (Open circuit)
2. Faulty control panel PCB (Heater ON/OFF button).
3. Faulty PCB.
4. Thermal fuse has melted (Error Code “14”).
Normal Value 0
(Melts at 216
°
C)
Normal Value
AC90~110V
Normal Value
AC90~110V
Normal Value
AC90~110V
Normal Value
0 (125V/3A)
NO