Rinnai RCE-560PTR Fan User Manual


 
Convector 460/560PTR - 30 - ©Rinnai
The unit will go into Test Mode when the Test Switch is switched ON while the unit is operating.
The unit will go into each of the following modes during Test Mode : Low Pressure Mode, High
Pressure Mode, Decision Level Adjustment Mode, and Sensitive Selection Mode.
Test Mode...................................................Disables the temperature controls and allows you to
change the level manually. (Cancels when the test
switch is turned on again, or when combustion ceases.)
The level can be raised/lowered with the temperature
control buttons “
” and “
”, however, if they are con-
tinuously pressed for at least 0.5 seconds, it will change
to level 12 or level 1.
Low Pressure Mode...................................The modulating valve electric current value for low
combustion can be adjusted with the temperature “
and “
” buttons. After adjusting, the data will be stored
when Timer 1 is switched ON.
High Pressure Mode .................................The modulating valve electric current value for high
combustion can be adjusted, with the temperature “
and “
” buttons. After adjusting, the data will be stored
when Timer 1 is switched ON.
Decision Level Adjustment Mode ...........The maximum flame failure detection level can be
adjusted with the temperature “
” button, and the mini-
mum with the temperature “
” button. They can be set
in the following order: 12mV, 14mV, 16mV, 18mV.
After adjusting, the data will be stored when Timer 1 is
switched ON.
Sensitivity Selection Mode .......................The sensitivity can be changed over from 1 to 2, and
vice versa, with the temperature “
” button. After
adjusting, the data will be stored when Timer 1 is
switched ON. It is factory set at sensitivity level 2.
* To reset each mode, press the ON/OFF button to turn the unit OFF.
* If the Timer 1 button is not pressed during each mode, the updated setting will be cancelled and
the data will not be stored in memory.
* If the data is stored, it will return to test mode and the entered information will be displayed.
Low Pressure Mode
High Pressure Mode
Decision Level
Adjustment Mode
Sensitivity
Selection Mode
Test ModeNormal OFF
T
e
s
t
B
u
t
t
o
n
o
n
c
e
T
i
m
e
r
1
B
u
t
t
o
n
T
e
s
t
B
u
t
t
o
n
t
w
o
t
i
m
e
s
T
i
m
e
r
1
B
u
t
t
o
n
T
e
s
t
B
u
t
t
o
n
t
h
re
e
t
i
m
e
s
T
i
m
e
r
1
B
u
t
t
o
n
T
i
m
e
r
1
B
u
tto
n
T
e
s
t
B
u
t
t
o
n
f
o
u
r
t
i
m
e
s
Test
Button