10. Unclean Filter Cartridge
<Smoke and odours are not removed> <Heater becomes noisy>
The replacement period for the filter cartridge will vary due to use and location of installa-
tion, however, it should be replaced yearly.
&RQGLWLRQVWKDWDUHQRWIDXOWV
Condition Cause and Explanation
Ignition is slow and cold air is
blown from appliance
When the ON/OFF switch is pressed, ignition occurs, however,
ignition could be delayed due to air in the gas supply line.
Combustion Indicator (red) will not illuminate until the thermocou-
ple has heated up. There will be a delay of a few seconds after igni-
tion.
Warm air continues to blow
even after switching appliance
OFF
The fan stops after releasing all residual heat from within the appli-
ance.
(approx. 255 secs if filter indicator flashes)
Clicking sound when the
burner ignites.
Normal ignition sound. The extent of the sound will depend on gas
pressure and burner temperature.
(Sound is of re-ignition straight after extinction.)
Resonant sound after ignition. Movement of the flame as it travels across the burner.
This will soon go.
After ignition/extinction there
is a ticking or clicking noise.
This is the sound of the combustion chamber metal expanding/
contracting due to heat, and is normal.
The heater does not ignite
upon initial use.
There may be air in the gas supply, preventing the appliance ignit-
ing immediately. If ignition does not occur after 30 seconds, the
spark will stop and the heater will lockout. Turn the heater off to
reset before attempting ignition again.
There is smoke or an unusual
smell upon initial use
There may be grease or a smell of smoke when first using the appli-
ance. This will stop after a short period. Increase the ventilation
when using the appliance.
Slight odour upon burner
ignition/extinction.
There may be a slight odour upon ignition/extinction of burner.
(This will go once flame becomes stable.)