Rinnai RCE-560PTR Fan User Manual


 
Convector 460/560PTR - 40 - ©Rinnai
b. The convection fan does not begin to rotate.
1. Convection fan shaft grub screw loose.
2. An obstruction in the convection fan is preventing the fan from rotating.
3. Open circuit or bad connection in motor circuit. (Error code "62")
4. Faulty PCB.
c. The solenoid valves do not open
1. Broken wiring or loose pin connectors.
2. Solenoid coil wiring is broken or shorted.
3. Faulty PCB. (No DC90V circuit to solenoid.)
d. There is no spark
1. High tension cord disconnected or broken.
2. Leak due to broken electrode etc.
3. Incorrect spark gap (Normal spark electrode gap is 2.2 ~ 3.0 mm).
4. Faulty PCB.
%$IWHUUHSHDWHGHIIRUWVWRRSHUDWHWKHDSSOLDQFHLWZLOOQRWLJQLWH(UURUFRGH³´
1RZDUPDLU
1. Air is in the gas supply.
2. Incorrect gas pressure (primary).
3. Incorrect gas type, or kink in the gas supply hose, or the hose is too long.
4. Faulty sparker.
5. Blocked injector.
6. Incorrect combustion specification. (Injector, restrictor, regulator pressure etc).
Motor Coil
Normal Value
150~300
SV
1
SV
2
Normal Value:
2.0~3.0k
Modulating
Valve
Normal Value
16~26