a. the air purifier fan does not begin to rotate.
Is there electrical supply? 1. Confirm the connection at the wall socket.
2. Is the 3 amp fuse blown?
a. The sequence does not continue.
1. Broken wiring or loose pin connectors. (Open circuit)
2. Faulty control panel PCB. (Air Purifier ON/OFF button)
3. Faulty PCB.
4. Loose primary filter. (Error code "05")
b. The air purifier fan does not begin to rotate.
1. Air purifier fan shaft grub screw loose.
2. An obstruction in the air purifier fan is preventing the fan from rotating.
3.
Open circuit or bad connection in motor circuit.
4. Faulty PCB.
YES
Normal Value
AC90~110V
Normal Value
0 (125V.3A)
Motor Coil Normal Value
60~150
NO