Panasonic KX-TA624 Air Conditioner User Manual


 
Telephone Features 3-123
3.3 Operator/Manager Service Features
Outgoing Message (OGM)
The operator or manager can record or play back the outgoing message.
This is played when a caller accesses the DISA feature.
Two Outgoing Messages (OGM 1 and OGM 2) are available for DISA 1 and DISA 2.
Recording a message
— Be sure that you are in the Station Programming mode. Set the MEMORY switch to
“PROGRAM”.
PT
Dial 9.
9
Lift the handset. Dial 0 for both OGM 1 and OGM 2.
Dial 1 for OGM 1.
Dial 2 for OGM 2.
Record a message
(up to 30 seconds).
Press AUTO DIAL/STORE.
AUTO DIAL
STORE
Confirmation
tone
Confirmation
tone
10
or
2
or
<PT Display Example>
Time counter
(seconds)
The STORE indicator light turns off. Recording
starts after the confirmation tone.
Record 1&2:00
The STORE indicator light turns steady red.
If you exceed the time (30 seconds), recording is stopped automatically.
— To exit the Station Programming mode, set the MEMORY switch to “SET”.