Panasonic FX-301 Home Safety Product User Manual


 
76
FX-301
100 3.937
50 1.969
35 1.378
מ
44 1.732
22 0.866
14 0.551
מ
100 3.937
50 1.969
35 1.378
מ
72 2.835
36 1.417
26 1.024
מ
320 12.598
160 6.299
120 4.724
מ
160 6.299
80 3.150
50 1.969
מ
120 4.724
60 2.362
35 1.378
מ
100 3.937
50 1.969
30 1.181
מ
36 1.417
18 0.709
12 0.472
מ
50 1.969
25 0.984
18 0.709
מ
22 0.866
11 0.433
7 0.276
מ
50 1.969
25 0.984
18 0.709
מ
32 1.260
16 0.630
10 0.394
מ
160 6.299
80 3.150
60 2.362
מ
160 6.299
80 3.150
50 1.969
מ
80 3.150
40 1.575
25 0.984
מ
46 1.811
23 0.906
16 0.630
מ
18 0.709
9 0.354
6 0.236
מ
"0.04 mm
"0.0016 in
opaque object
"0.02 mm
"0.0008 in
opaque object
"0.04 mm
"0.0016 in
opaque object
"0.06 mm
"0.0024 in
opaque object
"4 mm
"0.157 in
opaque object
"0.08 mm
"0.003 in
opaque object
"0.02 mm
"0.0008 in
opaque object
LIST OF FIBERS
Environment resistant
Heat-resistant
Vacuum
Chemical-resistant
Environment resistant fibers [Thru-beam type (one pair set)]
:LONG
:STD
:FAST
:S-D
Sensing range (mm in) (Note 1)
Red LED
Blue LED
Green LED
Infrared LED
550 21.654
280 11.024
200 7.874
100 3.937
200 7.874
300 11.811
1,000 39.370
1,000 39.370
280 11.024
165 6.496
75 2.953
90 3.543
310 12.205
140 5.512
50 1.969
880 34.646
440 17.323
155 6.102
550 21.654
280 11.024
90 3.543
3,500 137.795
1,500 59.055
530 20.866
470 18.504
230 9.055
80 3.150
220 8.661
100 3.937
35 1.378
800 31.496
400 15.748
140 5.512
3,500 137.795
1,500 59.055
530 20.866
420 16.535
210 8.268
160 6.299
מ
220 8.661
110 4.331
70 2.756
מ
420 16.535
210 8.268
160 6.299
מ
70 2.756
35 1.378
25 0.984
מ
320 12.598
160 6.299
120 4.724
מ
400 15.748
200 7.874
150 5.906
מ
75 2.953
38 1.496
24 0.945
מ
70 2.756
35 1.378
22 0.866
מ
28 1.102
14 0.551
10 0.394
מ
Notes: 1)
Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. In addition, the infrared
type is easily affected by humidity, so contact our office if using these sensors in environments with high humidity or where humidity levels can fluctuate.
Notes: 2)
The minimum sensing object size is the value for red LED type. Please contact our office for information on the minimum sensing object size if using amplifiers other than red
LED type.The optimum condition is the condition when the sensitivity is set so that the sensing output just changes to light incident operation in the object absent
condition.
Notes: 3) The allowable cutting range is 500 mm 19.685 in from the end that the amplifier inserted.
Lens mountable
Side-view
350 ЊC 662 ЊF
Lens mountable
200 ЊC 392 ЊF
Lens mountable
130 ЊC 266 ЊF
Lens mountable
Easy mounting Rectangular head
SEMI S2 compliant
W7
ן
H15
ן
D13
W0.276
ן
H0.591
ן
D0.512
350 ЊC 662 ЊF
Sleeve 60 mm 2.362 in
Allows flexible wiring
200 ЊC 392 ЊF
Lens mountable
R25 mm
R0.984 in
R25 mm
R0
.984 in
R25 mm
R
0.984 in
R30 mm
R1.181 in
R200 mm
R7.874 in
R30 mm
R1.181 in
FT-H35-M2
FT-H35-M2S6
FT-H20W-M1
FT-H20W-M2
FT-H20-M1
FT-H13-FM2
FT-L8Y
FT-V8Y
FT-6V
FT-60V
Allowable
bending
radius
Model No.
R10 mm
R0.394 in
R10 mm
R0.394 in
FT-Z802Y
The vacuum type fiber must be used with the following products as a set.
FT-J6: Fiber at atmospheric side (one pair set) FV-BR1: Photo-terminal (one pair set)
Semi-standard fibers (Custom made per order)
The fiber cable length or sleeve length of the standard fibers can be modified at your request. Select the fiber cable length (symbol ) or the sleeve length
(symbol f ) from the table below.
FT-FM
FT-FM -S f
FT-FM L
FT-NFM2-S f
FT-WA30-
FT-WA8-
FT-A30-
FT-A8-
FT-H20-M
FT-H35-M
FT-Z80 Y
3 9.843, 4 13.123, 5 16.404, 10 32.808,
15 49.213, 20 65.617,25 82.021, 30 98.425
2 6.562 (Note), 3 9.843, 4 13.123, 5 16.404,
10 32.808, 15 49.213, 20 65.617, 25 82.021, 30 98.425
20 65.617, 30 98.425
5 16.404
2 6.562, 3 9.843
3 9.843
5 16.404, 7 22.966
Standard threaded
head (free-cut)
With sleeve
With large diameter lens
Small diameter threaded
head with sleeve (free-cut)
Wide beam
200ЊC 392ЊF heat-resistant
350ЊC 662ЊF heat-resistant
Chemical-resistant
Correlation between sensing
range attenuation coefficient and
fiber cable length
The longer the fiber cable, the shorter the
sensing range.
1 0.394, 2 0.787, 3 1.181, 4 1.575, 5 1.969, 6 2.362,
7 2.756, 8 3.150, 9 3.543, 10 3.937, 11 4.331, 12
4.724
1 0.394, 2 0.787, 3 1.181, 4 1.575, 5 1.969, 6 2.362,
7 2.756, 8 3.150, 9 3.543, 10 3.937, 11 4.331, 12
4.724
Note:
The standard fiber has a 2 m 6.562 ft fiber cable length and a 4 cm 1.575 in or 9 cm 3.543 in sleeve length.
Fiber
R25 mm
R0.984 in
Sleeve
Type
Shape of fiber head
(mm in)
2 m
6.562 ft
1 m
3.281 ft
2 m
6.562 ft
1 m
3.281 ft
1 m
3.281 ft
Type
Fiber cable length
(Unit: m ft)
f
Sleeve length
(Unit: cm in)
Min. sensing object
under the optimum
condition (Note 2)
Basic model No.
2 m
6.562 ft
2 m
6.562 ft
2 m
6.562 ft
(Note 3)
Fiber cable
length
:
Free-cut
08/2005