Panasonic FX-301 Home Safety Product User Manual


 
75
FX-301
R25 mm
R0.984 in
R25 mm
R0.984 in
600 23.622
300 11.811
220 8.661
מ
120 4.724
60 2.362
40 1.575
מ
120 4.724
60 2.362
40 1.575
מ
80 3.150
35 1.378
10 0.394
מ
3 0.118
2 0.079
1 0.039
מ
14 0.551
7 0.276
4 0.157
מ
130 5.118
64 2.520
45 1.772
מ
300 11.811
150 5.906
110 4.331
מ
60 2.362
30 1.181
20 0.787
מ
60 2.362
30 1.181
20 0.787
מ
מ
מ
מ
מ
1 0.039
מ
מ
מ
6 0.236
3 0.118
2 0.079
מ
64 2.520
32 1.260
22 0.866
מ
"0.25 mm
"0.010 in
opaque object
Horizontal:
"0.025 mm
"0.0010 in
opaque object
Vertical:
"0.45 mm
"0.018 in
opaque object
"0.06 mm
"0.0024 in
opaque object
"0.02 mm
"0.0008 in
opaque object
"0.02 mm
"0.0008 in
opaque object
"0.05 mm
"0.0020 in
opaque object
LIST OF FIBERS
Special use
Wide beam
Array
Narrow beam
Ultra-small diameter
Tough flexible
FT-A8
FT-AFM2
FT-AFM2E
FT-K8
FT-KV8
FT-KV1
FT-E12
FT-E22
FT-P81X
Special use fibers [Thru-beam type (one pair set)]
1,100 43.307
220 8.661
200 7.874
800 31.496
8 0.315
36 1.417
230 9.055
:LONG
:STD
:FAST
:S-D
Sensing range (mm in) (Note 1)
Red LED
Blue LED
Green LED
Infrared LED
Allowable
bending
radius
Model No.
3,500 137.795
1,500 59.055
750 29.528
650 25.591
330 12.992
115 4.528
590 23.228
290 11.417
100 3.937
2,000 78.740
1,000 39.370
350 13.780
18 0.709
10 0.394
3 0.118
180 7.087
500 19.685
250 9.843
100 3.937
80 3.150
50 1.969
15 0.591
650 25.591
320 12.598
110 4.331
220 8.661
110 4.331
80 3.150
מ
48 1.890
24 0.945
18 0.709
מ
48 1.890
24 0.945
18 0.709
מ
מ
מ
מ
מ
4 0.157
2 0.079
1.5 0.059
מ
10 0.394
5 0.197
3 0.118
מ
130 5.118
64 2.520
45 1.772
מ
Sensing width
32 mm
1.260 in
W5ןH69ןD20
W0.197ןH2.717ןD0.787
Sensing width
11 mm
0.433 in
W4.2
ן
H31
ן
D13.5
W0.165
ן
H1.220
ן
D0.531
Top sensing
W5
ן
H15
ן
D15 W0.197
ן
H0.591
ן
D0.591
Side sensing
W5
ן
H15
ן
D15 W0.197
ן
H0.591
ן
D0.591
Side-view
Beam diameter:
"
0.125 mm
"
0.005 in
Notes: 1) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. In addition, the
infrared type is easily affected by humidity, so contact our office if using these sensors in environments with high humidity or where humidity levels can
fluctuate.
Notes: 2) The minimum sensing object size is the value for red LED type. Please contact our office for information on the minimum sensing object size if using
amplifiers other than red LED type.
The optimum condition is the condition when the sensitivity is set so that the sensing output just changes to light incident operation in the object absent
condition.
Notes: 3) The fiber cable length practically limits the sensing range to 3,500 mm 137.795 in long.
R5 mm
R0.197 in
R10 mm
R0.394 in
R10 mm
R0.394 in
R10 mm
R0.394 in
R10 mm
R0.394 in
Sleeve part cannot be bent.
Beam diameter:
"
0.25 mm
"
0.010 in
Sleeve part cannot be bent.
Lens mountable
Type
Shape of fiber head
(mm in)
500 mm
19.685 in
1 m
3.281 ft
1 m
3.281 ft
Min. sensing object
under the optimum
condition (Note 2)
3,500 137.795
3,500 137.795
3,500 137.795
3,500 137.795
(Note 3)
2,400 94.488
1,200 47.244
700 27.559
מ
1,200 47.244
600 23.622
350 13.780
מ
800 31.496
400 15.748
240 9.449
מ
400 15.748
200 7.874
130 5.118
מ
200 7.874
100 3.937
65 2.559
מ
150 5.906
75 2.953
40 1.575
מ
"0.3 mm
"0.012 in
opaque object
FT-A30
2 m
6.562 ft
2 m
6.562 ft
2 m
6.562 ft
2 m
6.562 ft
2 m
6.562 ft
Side-view
W2ןH1.5ןD20
W0.079ןH0.059ןD0.787
Fiber cable
length
:
Free-cut
08/2005