101
FX-301
PRECAUTIONS FOR PROPER USE
Fiber
• Mount the fiber head by using the enclosed set of screws.
The tightening torque should be 0.15 N⅐m or less
• If the fiber head is mounted in places subject to vibrations
or shocks, use a screw-locking adhesive, etc.
• Mount each fiber head as given below.
Mounting FT-Z8Ⅺ and FT-WZ8Ⅺ
<FT-Z8 / FT-WZ8 (Front sensing type)>
In case of tapping the mounting section
<FT-Z8E / FT-WZ8E (Side sensing type)>
In case of tapping the mounting section
In case of using attached screw and nut
In case of using attached screw and nut
<FT-Z8H / FT-WZ8H (Top sensing type)>
In case of tapping the mounting section
In case of using attached screw and nut
• Using M3 pan head
screws, the tightening
torque should be
0.3 N⅐m or less.
Mounting FT-Z802Y
<If not using the attached mounting brackets>
• Use M3 or less set screws (cup point), and affix the head
within 15 mm 0.591 in from the tip of the fiber head. Do
not exceed a torque of 0.3 N⅐m when tightening.
<If using the attached mounting brackets>
• The head can be affixed even without using the set
screws.
• If using the set screws, use M3 set screws (cup point) to
affix and do not exceed a torque of 0.05 N⅐ m when
tightening.
Mounting FD-WKZ1
• Using M3 screws, the tightening torque should be 0.3 N⅐m
or less.
Mounting FD-A15
• Using M3 screws, the tightening torque should be 3 N⅐m
or less.
Mounting FD-H30-L32 / FD-H18-L31
08/2005