100
FX-301
M3
M4
M5
M6
M14
0.39 N·m
0.58 N·m
350 °C 662 °F heat-resistant fiber and
FT-H20W-MⅪ: 0.98 N⅐m,
FD-H35-20S: 0.58 N⅐m
0.98 N·m
350 °C 662 °F heat-resistant
fiber: 1.96 N⅐m
1.47 N⅐m
PRECAUTIONS FOR PROPER USE
Fiber
FT-PS1
FD-E12
FT-V22
FT-41, FD-V41
FT-SFM2SV2
FD-EG1
FT-WV42
FD-WV42
FD-SFM2SV2
FT-KV8, FT-WKV8
FT-V10
FT-K8
3 0.118
4 0.157
(Note 1)
10 0.394
10 0.394
15 0.591
7 0.276
13 0.512
12 0.472
0.1 N⅐m
0.29 N⅐m
0.19 N⅐m
0.29 N⅐m
0.29 N⅐m
0.34 N⅐m
0.3 N⅐m
Mounting
• The tightening torque must not exceed the values given
below.
• Using M3 screws, the tightening
torque should be 0.58 N⅐m or less.
• Fibers for which the tightening section has been specified
should be fixed at ?mm from the tightening section tip.
However, for FT-K8, FT-KV8, FT-WKV8 and FT-V10 ‘?’
indicates the range over which tightening cannot be done.
Mounting with a nut (threaded head type)
Mounting with a set screw
Mounting array fiber
Tightening torque
? (mm in)
Tightening torque
Tightening torque: 0.29 N⅐m or less
FT-SFM2L: 0.19 N⅐m
FT-H20W-MⅪ: 0.49 N⅐m
<
FT-K8, FT-KV8, FT-WKV8, FT-V10
>
()
()
()
• Using M3 counter-
sunk head screws,
the tightening torque
should be 0.3 N⅐ m
or less.
Mounting FD-WL41 / FD-L41 and FD-WL42 / FD-L42
• Using M3 counter-
sunk head screws,
the tightening torque
should be 0.3 N⅐ m
or less.
Mounting FD-L43
<FD-WL41 / FD-L41>
<FD-WL42 / FD-L42>
• Using M2.6 (length
12 mm 0.472 in)
screws with
washers
(accessory),
the
tightening torque
should be 0.3 N⅐ m
or less.
Mounting FD-L4
()
Notes 1): Excluding the sleeve.
Notes 2):When installing, make sure to use
screws smaller than the fiber
diameter.
08/2005