Nordyne RC 92+ Furnace User Manual


 
9
Table 3. Furnace Dimensions and Shipping Weights
Table 4. Minimum Clearances to Combustible Materials
CLEARANCES TO COMBUSTIBLE MATERIALS
This furnace is Designed Certifi ed by CSA International for the minimum clearances to combus-
tible material listed in Table 4. See the furnace name plate, located inside the furnace cabinet, for
specifi c model number and clearance information.
services both the appliance and the
carbon monoxide detector;
b. Have battery back-up power;
c. Meet ANSI/UL 2034 Standards
and comply with NFPA 720 (2005
Edition);and
d. Have been approved and listed by
a Nationally Recognized Testing
Laboratory as recognized under 527
CMR.
3. A Product-approved vent terminal must
be used, and if applicable, a Product-
approved air intake must be used. In-
stallation shall be in strict compliance
with the manufacturer’s instructions. A
copy of the installation instructions shall
remain with the appliance or equipment
at the completion of the installation.
4. A metal or plastic identifi cation plate
shall be mounted at the exterior of the
building, four feet directly above the lo-
cation of vent terminal. The plate shall
be of suffi cient size to be easily read
from a distance of eight feet away, and
read “Gas Vent Directly Below”.
Model
Number
Furnace
Btuh
Dimensions (inches)
Shipping
Weight
(lbs
)
ABCD
*RC040 40,000 14 1/4 12 3/4 5 1/8 11 3/4 133
*RC060 60,000 14 1/4 12 3/4 5 1/8 11 3/4 140
*RC080 80,000 19 3/4 18 1/4 7 7/8 17 1/4 172
*RC100 100,000 19 3/4 18 1/4 7 7/8 17 1/4 180
*RC120 120,000 22 1/2 21 9 1/4 20 204
*RL040 40,000 14 1/4 12 3/4 4 5/8 12 3/4 135
*RL060 60,000 14 1/4 12 3/4 4 5/8 12 3/4 135
*RL080 80,000 19 3/4 18 1/4 10 18 1/4 174
*RL100 100,000 19 3/4 18 1/4 10 18 1/4 185
*RL120 120,000 22 1/2 21 12 1/2 21 1/8 209
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIAL
Furnace Cabinet Minimum Clearances (Inches)
Input Width
(Btuh) (Inches) Side Vent Back Top Front
40,000 14 1/4 00011*
60,000 14 1/4 00011*
80,000 14 1/4 00011*
100,000 19 3/4 00011*
120,000 22 1/2 00011*
* When installed horizontally, 24 inches is required for servicing.